EFFECT OF ANALYZER ON DETERMINATION OF MIXED VENOUS PCO2 AND CARDIAC-OUTPUT DURING EXERCISE

被引:7
作者
HORNBY, L [1 ]
COATES, AL [1 ]
LANDS, LC [1 ]
机构
[1] MCGILL UNIV,MONTREAL CHILDRENS HOSP,DIV RESP MED,MONTREAL,PQ H3H 1P3,CANADA
关键词
NONDISPERSIVE INFRARED ANALYZER; MASS SPECTROMETER; CARBON DIOXIDE;
D O I
10.1152/jappl.1995.79.3.1032
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Cardiac output (CO) during exercise can be determined noninvasively by using the indirect Fick CO2-rebreathing technique. CO2 measurements for this technique are usually performed with an infrared analyzer (IA) or mass spectrometer (MS). However, IA CO2 measurements are susceptible to underreading in the face of high O-2 concentrations because of collision broadening. We compared an IA (Ametek model CD-3A) with a MS (Marquette model MGA-1100) to see the effect this would have on mixed venous PCO2 (PVCO2) and CO measurements. After calibration with room air and a gas mixture of 5% CO2-12% O-2-83% N-2, both devices were tested with three different gas mixtures of CO2 in O-2. For each gas mixture, IA gave lower CO2 values than did the MS (4.1% CO2: IA, 3.85 +/- 0.01% and MS, 4.13 +/- 0.01%; 9.2% CO2: IA, 8.44 +/- 0.07% and MS, 9.19 +/- 0.01%; 13.8% CO2: IA, 12.57 +/- 0.15% and MS, 13.82 +/- 0.01%). Warming and humidifying the gases did not alter the results. The IA gave lower values than did the MS for eight other medical gases in lower concentrations of O-2 (40-50%). Equilibrium and exponential rebreathing procedures were performed. Values determined by the IA were > 10% higher than those determined by the MS for both rebreathing methods. We conclude that all IAs must be checked for collision broadening if they are to be used in environments where the concentration of O-2 is >21%. If collision broadening is present, then either a special high O-2-CO2 calibration curve must be constructed, or the IA should not be used for both arterial PCO2 and PVCO2 estimates because it may produce erroneously low PVCO2 values, with resultant overestimation of CO.
引用
收藏
页码:1032 / 1038
页数:7
相关论文
共 14 条
[1]   MEASUREMENT OF MIXED VENOUS CARBON-DIOXIDE PRESSURE BY REBREATHING DURING EXERCISE [J].
DASILVA, GA ;
ELMANSHAWI, A ;
HEIGENHAUSER, GJF ;
JONES, NL .
RESPIRATION PHYSIOLOGY, 1985, 59 (03) :379-392
[2]  
FAULKNER JA, 1977, MED SCI SPORT EXER, V9, P148
[3]   COMPARISON OF 2 REBREATHING METHODS FOR THE DETERMINATION OF MIXED VENOUS PARTIAL-PRESSURE OF CARBON-DIOXIDE DURING EXERCISE [J].
HEIGENHAUSER, GJF ;
JONES, NL .
CLINICAL SCIENCE, 1979, 56 (05) :433-437
[4]  
JACKSON AC, 1984, TECHNIQUES LIFE SCI, P1
[5]   INFLUENCE OF AGE AND STATURE ON EXERCISE CAPACITY DURING INCREMENTAL CYCLE ERGOMETRY IN MEN AND WOMEN [J].
JONES, NL ;
SUMMERS, E ;
KILLIAN, KJ .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (05) :1373-1380
[6]   EFFECT OF PCO2 LEVEL ON ALVEOLAR-ARTERIAL PCO2 DIFFERENCE DURING REBREATHING [J].
JONES, NL ;
CAMPBELL, EJ ;
KANE, JW ;
ROBERTSON, DG .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (06) :782-+
[7]   REBREATHING EQUILIBRATION OF CO2 DURING EXERCISE [J].
JONES, NL ;
REBUCK, AS .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (04) :538-541
[8]   DIFFERENCE BETWEEN END-TIDAL AND ARTERIAL PCO2 IN EXERCISE [J].
JONES, NL ;
ROBERTSON, DG ;
KANE, JW .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (05) :954-960
[9]   CARDIAC-OUTPUT DETERMINATION DURING PROGRESSIVE EXERCISE IN CYSTIC-FIBROSIS [J].
LANDS, LC ;
HEIGENHAUSER, GJF ;
JONES, NL .
CHEST, 1992, 102 (04) :1118-1123
[10]  
MCHARDY GJR, 1967, CLIN SCI, V32, P299