SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL

被引:149
作者
APPLEGATE, RJ
CHENG, CP
LITTLE, WC
机构
[1] Department of Medicine, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, NC
[2] Bowman Gray School of Medicine, Cardiology Department, Winston-Salem, NC 27103
关键词
Left ventricle; Pressure-volume relations; Ventricular function;
D O I
10.1161/01.CIR.81.2.638
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared left ventricle (LV) volume (V) simultaneously measured using the conductance catheter (VM) with volume calculated from three LV dimensions (VD) determined ultrasonically from endocardial crystals. Seven adult mongrel dogs (20-30 kg) were anesthetized and instrumented to measure micromanometer LV pressure and V. Three pairs of crystals were placed orthogonally in subendocardial positions and a conductance catheter was placed in the LV retrograde across the aortic valve. Under steady-state conditions, over the range of a single cardiac cycle, the relation between VM and VD was well described by a straight line. There was an excellent correlation of conductance and dimension volumes with r equal to 0.97±0.04 and SEE 0.8±0.5 ml. The gain (1/α) and parallel conductance volume (αVc) were constant. At lower volumes obtained during bicaval occlusion, however, the relation between VM and VD was curvilinear. 1/α and αVc both decreased as LVV fell. Thus, determination of absolute volume using the conductance catheter depended on the conditions under which the data were obtained. Under steady-state conditions, αVc calculated by both the saline method (mean±SD, 50±15 ml) and by regression of VM and VD, (45±21 ml) were similar. Consequently, absolute LV end-diastolic volumes and end-systolic volumes by the conductance and dimension methods were similar (53±14 ml and 38±14 ml vs. 56±17 ml and 44±16 ml, respectively, p=NS). When volume decreased during bicaval occlusion, there was a progressively greater decrease in VM as compared with VD. The absolute slope (EES) of the end-systolic pressure-volume relation (ESPVR) was consistently higher by the dimension method, group average, 16.3±7.6, than by the catheter, 8.5±5.9, p<0.05. The direction and magnitude of the change in EES at different inotropic states (autonomic blockade; dobutamine), however, was similarly measured by both the conductance catheter and dimension method. We conclude that the gain and offset of the conductance catheter are relatively constant at steady state but vary when volume is reduced by caval occlusion. Thus, the conductance catheter accurately measures absolute volumes at steady state but can underestimate the slope and position of the ESPVR when it is determined by caval occlusion. The conductance catheter does, however, accurately measure the directions and magnitude of change in contractile state.
引用
收藏
页码:638 / 648
页数:11
相关论文
共 33 条
  • [1] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [2] CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER
    BAAN, J
    JONG, TTA
    KERKHOF, PLM
    MOENE, RJ
    VANDIJK, AD
    VANDERVELDE, ET
    KOOPS, J
    [J]. CARDIOVASCULAR RESEARCH, 1981, 15 (06) : 328 - 334
  • [3] BAAN J, 1982, CARDIOVASCULAR SYSTE, P569
  • [4] BISHOP VS, 1970, AM HEART J, V4, P507
  • [5] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [6] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [7] EFFECTS OF RESPIRATION AND VASODILATION ON VENOUS VOLUME IN ANIMALS AND MAN, AS MEASURED WITH AN IMPEDANCE CATHETER
    FERGUSON, JJ
    MILLER, MJ
    SAHAGIAN, P
    AROESTY, JM
    MCKAY, RG
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 16 (01): : 25 - 34
  • [8] INFLUENCE OF HEART-RATE ON LEFT-VENTRICULAR PERFORMANCE IN CONSCIOUS DOGS
    FREEMAN, GL
    LITTLE, WC
    OROURKE, RA
    [J]. CIRCULATION RESEARCH, 1987, 61 (03) : 455 - 464
  • [9] DYNAMIC DETERMINANTS OF LEFT-VENTRICULAR DIASTOLIC PRESSURE-VOLUME RELATIONS IN MAN
    GAASCH, WH
    COLE, JS
    QUINONES, MA
    ALEXANDER, JK
    [J]. CIRCULATION, 1975, 51 (02) : 317 - 323
  • [10] SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST
    GEDDES, LA
    BAKER, LE
    [J]. MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03): : 271 - &