POLY(96L/4D-LACTIDE) IMPLANTS FOR REPAIR OF ORBITAL FLOOR DEFECTS - AN IN-VITRO STUDY OF THE MATERIAL PROPERTIES IN A SIMULATION OF THE HUMAN ORBIT

被引:5
作者
CORDEWENER, FW [1 ]
ROZEMA, FR [1 ]
JOZIASSE, CAP [1 ]
BOS, RRM [1 ]
BOERING, G [1 ]
PENNINGS, AJ [1 ]
机构
[1] UNIV GRONINGEN,DEPT POLYMER CHEM,9747 AG GRONINGEN,NETHERLANDS
关键词
D O I
10.1007/BF00121279
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To test the mechanical and physical properties of two types of poly(96L/4D-lactide) (PLA96) implants and to evaluate their suitability for repair of large orbital floor defects, a study using an in vitro set-up was performed. Implants, 0.2 mm thick and 28 mm in diameter, were produced by either an extrusion process (type A) or by direct machining (type B) and had a molecular weight (($) over bar M(w))) of 64 x 10(3) and 146 x 10(3) g/mole, respectively, after gamma-sterilization with a dose of 25 kGy. The implants were tested over 8 weeks in an apparatus simulating the human orbit with a 3.1 cm(2) orbital floor defect under a static load corresponding to a retrobulbar pressure of 13 mm Hg as well as unloaded. Both implant types were able to counteract the applied static load without fracturing or excessive sagging. The type A implants sagged more than the type B implants (2.3 +/- 0.1 mm versus 1.0 +/- 0.0 mm, p < 0.01) but retained and even increased their strength during the study whereas the type B implants showed a gradual strength-loss. In the clinical setting the observed sagging in both types would not have resulted in positional changes of the eyeball. it is concluded that with respect to the mechanical properties, both types of PLA96 implants tested are suitable for repair of large orbital floor defects.
引用
收藏
页码:561 / 568
页数:8
相关论文
共 40 条
  • [1] FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES
    BERGSMA, EJ
    ROZEMA, FR
    BOS, RRM
    DEBRUIJN, WC
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) : 666 - 670
  • [2] LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS
    BERGSMA, JE
    DEBRUIJN, WC
    ROZEMA, FR
    BOS, RRM
    BOERING, G
    [J]. BIOMATERIALS, 1995, 16 (01) : 25 - 31
  • [3] BURRES SA, 1981, LARYNGOSCOPE, V91, P1881
  • [4] CONVERSE JM, 1976, S PLASTIC SURGERY OR, P79
  • [5] CUTRIGHT DE, 1972, ORAL SURG ORAL MED O, V33, P28, DOI 10.1016/0030-4220(72)90204-6
  • [6] DEMAN K, 1982, THESIS BOHN, P51
  • [7] DUTTON JJ, 1991, SURV OPHTHALMOL, V35, P279
  • [8] GERLACH KL, 1988, THESIS C HANSER VERL, P31
  • [9] SYNTHESIS AND HYDROLYTIC DEGRADATION BEHAVIOR OF HIGH-MOLECULAR-WEIGHT L-LACTIDE AND GLYCOLIDE COPOLYMERS
    GRIJPMA, DW
    NIJENHUIS, AJ
    PENNINGS, AJ
    [J]. POLYMER, 1990, 31 (11) : 2201 - 2206
  • [10] RADIATION EFFECTS ON POLY(LACTIC ACID)
    GUPTA, MC
    DESHMUKH, VG
    [J]. POLYMER, 1983, 24 (07) : 827 - 830