EMG ARTIFACT MINIMIZATION DURING CLINICAL EEG RECORDINGS BY SPECIAL ANALOG FILTERING

被引:31
作者
BARLOW, JS
机构
[1] TUFTS UNIV, NEW ENGLAND MED CTR, DEPT NEUROL, BOSTON, MA 02111 USA
[2] VET ADM MED CTR JAMAICA PLAIN, DEPT NEUROL, BOSTON, MA 02130 USA
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1984年 / 58卷 / 02期
关键词
D O I
10.1016/0013-4694(84)90030-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multichannel analog filter for minimizing EMG [electromyogram] artifact in routine EEG recordings is described in tests on healthy volunteers. A 20 channel readily portable version was implemented which can be easily interfaced with standard EEG at the auxiliary input/output connectors, in such a way that the filter can be inserted or removed for all channels simultaneously, or selected channels can be filtered individually. That such an on-line filter be explored was suggested by the remarkable results for minimizing EMG artifact from EEG recordings at seizure onset by off-line computer-based digital filtering recently reported by Gotman, Ives and Gloor. A 4 pole Butterworth filter, i.e., having a maximally flat amplitude response in the passband and having a cut-off frequency, i.e., 30% attenuation point of 12.5 Hz was selected, the same cut-off frequency as that of the digital filter used by Gotman et al. With this cut-off frequency, which represents a compromise, residual EMG artifact is relatively small. With higher cut-off frequencies, EMG artifact can appear as pseudo-.beta. activity. Minimization of pseudo-.beta. activity is obtained at the expense of the elimination of true .beta. activity. Activity of .alpha. frequencies or lower can be readily identified in the filter output, even with severe EMG artifact in the unfiltered EEG. Other problems in EMG filtering are discussed. Since the analog filter has a non-linear phase characteristic, in contrast to the linear phase characteristic of the finite-impulse-response digital filter used by Gotman et al., the possibility existed that distortion of the wave form of EEG spikes could result, as well as attenuation of their amplitudes. The wave forms of filtered spikes in the write-out of the analog filter were found to be essentially identical with those from a 1-channel on-line finite-impulse-response computer-based filter having a linear phase characteristic. Phase shift in the analog filter is not a problem, at least for clinical EEG.
引用
收藏
页码:161 / 174
页数:14
相关论文
共 19 条
[1]  
Barlow J.S., 1976, Quantitative Analytic Methods in Epilepsy, P309
[2]   MUSCLE SPIKE ARTIFACT MINIMIZATION IN EEGS BY TIME-DOMAIN FILTERING [J].
BARLOW, JS .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 55 (04) :487-491
[3]   16-CHANNEL CASSETTE TAPE-RECORDER SYSTEM FOR CLINICAL EEGS [J].
BARLOW, JS .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 38 (02) :183-186
[4]  
BARLOW JS, 1983, ELECTROEN CLIN NEURO, V56, pP29
[5]  
BARLOW JS, 1977, ELECTROEN CLIN NEURO, V43, P569
[6]  
BARLOW JS, 1977, ZH VYSSH NERV DEYAT+, V27, P860
[7]  
BARLOW JS, 1975, ELECTROEN CLIN NEURO, V39, P208
[8]  
EBE M, 1973, ELECTROEN CLIN NEURO, V34, P706
[9]   CORRELATION OF CRITERIA USED FOR LOCALIZING EPILEPTIC FOCI IN PATIENTS CONSIDERED FOR SURGICAL THERAPY OF EPILEPSY [J].
ENGEL, J ;
RAUSCH, R ;
LIEB, JP ;
KUHL, DE ;
CRANDALL, PH .
ANNALS OF NEUROLOGY, 1981, 9 (03) :215-224
[10]  