WHITE COAT HYPERGLYCEMIA - DISPARITY BETWEEN DIABETES CLINIC AND HOME BLOOD-GLUCOSE CONCENTRATIONS

被引:12
作者
CAMPBELL, LV [1 ]
ASHWELL, SM [1 ]
BORKMAN, M [1 ]
CHISHOLM, DJ [1 ]
机构
[1] ST VINCENTS HOSP,GARVAN INST MED RES,SYDNEY,NSW 2010,AUSTRALIA
关键词
D O I
10.1136/bmj.305.6863.1194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives-To identify patients with discrepantly high clinic blood glucose concentrations compared with self reported values and to assess whether such patients have errors in self monitoring technique. To determine whether, in patients with good technique, the discrepancy is a transient phenomenon related to clinic attendance. Design-Prospective study of diabetes clinic patients recruited over six months. Setting-Outpatient diabetes clinic of a teaching hospital. Subjects-34 consecutive patients with noninsulin dependent diabetes who had had at least two consecutive clinic blood glucose concentrations more than 5 mmol/l higher than the mean self reported concentration. Main outcome measures-Assessment of monitoring technique; presence of cognitive or physical impairment; serum fructosamine concentration; home and clinic blood glucose concentrations. Results-15 of 34 patients had errors in monitoring technique, 12 of whom had cognitive or physical impairment. In the remaining 19, the mean (SD) blood glucose concentrations of capillary and venous samples taken at home (10.2 (0.6) and 12.2 (1.1) mmol/l respectively) were significantly lower than in those taken at the clinic (16.8 (1.6) mmol/l, p<0.0002). The fructosamine concentration was significantly higher in patients with monitoring errors than those without (2.4 (0.4) v 1.8 (0.4) mmol/l, p<0.0001). Conclusions-"White coat" hyperglycaemia was detected in about half the patients but errors in technique accounted for the rest of the discrepancies. Patients' ability should be assessed before teaching self monitoring and the technique checked regularly.
引用
收藏
页码:1194 / 1196
页数:3
相关论文
共 10 条
[1]  
[Anonymous], 1987, DIABETES CARE, V10, P95
[2]   OFFICE HYPERTENSION IN TYPE-2 (NON-INSULIN-DEPENDENT) DIABETIC-PATIENTS [J].
BURGESS, E ;
MATHER, K ;
ROSS, S ;
JOSEFSBERG, Z .
DIABETOLOGIA, 1991, 34 (09) :684-684
[3]  
CAMPBELL LV, 1991, DIABETES, V40, P140
[4]   DEVELOPMENT OF A SALIVARY CORTISOL METHOD FOR DETECTING CHANGES IN PLASMA-FREE CORTISOL ARISING FROM ACUTE STRESS IN SHEEP [J].
FELL, LR ;
SHUTT, DA ;
BENTLEY, CJ .
AUSTRALIAN VETERINARY JOURNAL, 1985, 62 (12) :403-406
[5]  
Long J, 1990, Md Med J, V39, P555
[6]  
MCLAY J, 1987 P AUSTR DIAB ED, pE3
[7]   MEASURING ADEQUACY OF DIABETES REGULATIONS - COMPARISON OF CONTINUOUSLY MONITORED BLOOD-GLUCOSE PATTERNS WITH VALUES AT SELECTED TIME POINTS [J].
MOLNAR, GD ;
TAYLOR, WF ;
LANGWORTHY, A .
DIABETOLOGIA, 1974, 10 (02) :139-143
[8]  
ROSE RM, 1981, TXB ENDOCRINOLOGY, P654
[9]  
SCHLEICHER ED, 1990, CLIN CHEM, V36, P136
[10]   THE EFFECTS OF RELAXATION ON GLUCOSE-TOLERANCE IN NON-INSULIN-DEPENDENT DIABETES [J].
SURWIT, RS ;
FEINGLOS, MN .
DIABETES CARE, 1983, 6 (02) :176-179