摘要
Background: Mechanical ventilator circuits are commonly changed at 48-h intervals. This frequency may be unnecessary because ventilator-associated pneumonia often results from aspiration of pharyngeal secretions and not from the ventilator circuit, We compared the ventilator-associated pneumonia rates and costs associated with 48-h and 7-day circuit changes. Methods: Ventilator circuits were changed at 48-h intervals during the control period (November 1992 to April 1993) and at 7-day intervals during the study period (June 1993 to November 1993). Nosocomial pneumonias were prospectively identified using the criteria of the Centers for Disease Control and Prevention, The annual cost difference of changing circuits at 48-h and 7-day intervals was calculated using the distribution of ventilator days for the control and study periods. Results: There were 1,708 patients, 9,858 ventilator days, and a pneumonia rate of 9.64 per 1,000 ventilator days in the control group (48-h circuit changes), There were 1,715 patients, 9,160 ventilator days, and 8.62 pneumonias per 1,000 ventilator days when circuits were changed at 1-week intervals (study group), Using a logistic regression model, there were significantly greater odds of developing a ventilator-associated pneumonia in surgical patients (odds ratio 1.77, P = 0.02) and patients in critical care units (odds ratio 1.54, P = 0.05), but no significant risk of ventilator-associated pneumonia in patients in whom circuits were changed at 1-week intervals (odds ratio 0.82, P = 0.22). Changing circuits at 7-day intervals resulted in a 76.6% ($111,530) reduction in the annual cost for materials and salaries. Conclusions: We found no difference in pneumonia rates with ventilator circuit changes at 48-h and 7-day intervals. Ventilator circuits can be safely changed at weekly intervals, resulting in large cost savings.
引用
收藏
页码:903 / 911
页数:9
相关论文
共 30 条
[1]  
AERDTS SJA, 1993, BRIT MED J, V307, P525
[2]  
BRITT MR, 1978, JAMA-J AM MED ASSOC, V239, P1047
[3]   NOSOCOMIAL PNEUMONIA AND THE ROLE OF GASTRIC PH - A METAANALYSIS [J].
COOK, DJ ;
LAINE, LA ;
GUYATT, GH ;
RAFFIN, TA .
CHEST, 1991, 100 (01) :7-13
[4]   CONTAMINATION OF MECHANICAL VENTILATORS WITH TUBING CHANGES EVERY 24 OR 48 HOURS [J].
CRAVEN, DE ;
CONNOLLY, MG ;
LICHTENBERG, DA ;
PRIMEAU, PJ ;
MCCABE, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 306 (25) :1505-1509
[5]   PREVENTING NOSOCOMIAL PNEUMONIA - STATE-OF-THE-ART AND PERSPECTIVES FOR THE 1990S [J].
CRAVEN, DE ;
STEGER, KA ;
BARBER, TW .
AMERICAN JOURNAL OF MEDICINE, 1991, 91 :S44-S53
[6]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[7]  
CRAVEN DE, 1986, AM REV RESPIR DIS, V133, P792
[8]  
DJEDAINI K, 1993, AM REV RESPIR DIS, V147, pA38
[9]   PROSPECTIVE-STUDY OF NOSOCOMIAL PNEUMONIA AND OF PATIENT AND CIRCUIT COLONIZATION DURING MECHANICAL VENTILATION WITH CIRCUIT CHANGES EVERY 48 HOURS VERSUS NO CHANGE [J].
DREYFUSS, D ;
DJEDAINI, K ;
WEBER, P ;
BRUN, P ;
LANORE, JJ ;
RAHMANI, J ;
BOUSSOUGANT, Y ;
COSTE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (04) :738-743
[10]   NOSOCOMIAL PNEUMONIA IN INTUBATED PATIENTS GIVEN SUCRALFATE AS COMPARED WITH ANTACIDS OR HISTAMINE TYPE-2 BLOCKERS - THE ROLE OF GASTRIC COLONIZATION [J].
DRIKS, MR ;
CRAVEN, DE ;
CELLI, BR ;
MANNING, M ;
BURKE, RA ;
GARVIN, GM ;
KUNCHES, LM ;
FARBER, HW ;
WEDEL, SA ;
MCCABE, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (22) :1376-1382