MAGNUM MAGNARAIL VERSUS CONVENTIONAL SYSTEMS FOR RECANALIZATION OF CHRONIC TOTAL CORONARY OCCLUSIONS - A RANDOMIZED COMPARISON

被引:31
作者
PANDE, AK [1 ]
MEIER, B [1 ]
URBAN, P [1 ]
DELASERNA, F [1 ]
VILLAVICENCIO, R [1 ]
DORSAZ, PA [1 ]
FAVRE, J [1 ]
机构
[1] UNIV GENEVA,HOP CANTONAL,CTR CARDIOL,CH-1211 GENEVA 4,SWITZERLAND
关键词
D O I
10.1016/0002-8703(92)91020-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Magnum/Magnarail system consists of "over-the-wire" balloon catheters and a 0.021 inch (0.53 mm) guide wire with a 1 mm olive-shaped tip. To compare it to conventional systems, 100 consecutive unselected patients with chronic total coronary occlusions were randomly assigned to one of two groups. If the balloon could not be placed within 20 minutes of fluoroscopy time with the allocated system, a crossover to the other system was imposed. The Magnum group comprised 50 patients and 52 occlusions, and the conventional group included 50 patients and 51 occlusions. There were no significant differences with regard to the length of the occlusions (Magnum 1.4 +/- 1.3 mm, conventional 1.6 +/- 1.7 mm) or the duration (Magnum 1.4 +/- 1.9 months, conventional 1.4 +/- 1.8 months). The primary success rate before crossover with the Magnum/Magnarail system was 67% versus 45% with conventional systems (p < 0.05). The Magnum/Magnarail system as a second tool after crossover was successful in 11 of 28 patients (39%) versus 2 of 16 patient (12%) in whom success was achieved with a conventional system as a second tool (p < 0.05). An increase in the creatine kinase level (more than twice normal) was seen in one patient (2%) in the Magnum/Magnarail group and none in the conventional group. Q wave infarctions were not seen. There was one in-hospital death (2%) in the conventional group. There were no significant differences with regard to the number of guiding and balloon catheters or fluoroscopy time. The Magnum/Magnarail system proved superior to conventional systems for balloon recanalization of chronic total coronary occlusions in terms of higher success rates.
引用
收藏
页码:1182 / 1186
页数:5
相关论文
共 16 条
[1]   USE OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - RESULTS OF A CURRENT SURVEY [J].
BAIM, DS ;
IGNATIUS, EJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (14) :G3-G8
[2]   TRANS-LUMINAL ANGIOPLASTY OF OCCLUDED CORONARY-ARTERIES - USE OF A MOVABLE GUIDE WIRE SYSTEM [J].
DERVAN, JP ;
BAIM, DS ;
CHERNILES, J ;
GROSSMAN, W .
CIRCULATION, 1983, 68 (04) :776-784
[3]   LONG-TERM RESULTS OF SUCCESSFUL AND FAILED ANGIOPLASTY FOR CHRONIC TOTAL CORONARY ARTERIAL-OCCLUSION [J].
FINCI, L ;
MEIER, B ;
FAVRE, J ;
RIGHETTI, A ;
RUTISHAUSER, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (07) :660-662
[4]   CLINICAL-EXPERIENCE WITH THE MONORAIL BALLOON CATHETER FOR CORONARY ANGIOPLASTY [J].
FINCI, L ;
MEIER, B ;
ROY, P ;
STEFFENINO, G ;
RUTISHAUSER, W .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (03) :206-212
[5]   INTRAOPERATIVE EVALUATION OF FUNCTIONAL SIGNIFICANCE OF CORONARY COLLATERAL VESSELS IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
FLAMENG, W ;
SCHWARZ, F ;
HEHREIN, FW .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 42 (02) :187-192
[6]   ANGIOPLASTY IN TOTAL CORONARY-ARTERY OCCLUSION [J].
HOLMES, DR ;
VLIETSTRA, RE ;
REEDER, GS ;
BRESNAHAN, JF ;
SMITH, HC ;
BOVE, AA ;
SCHAFF, HV .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (03) :845-849
[7]  
HOMES DR, 1985, HERZ, V74, P292
[8]   ANGIOPLASTY IN TOTAL CORONARY-ARTERY OCCLUSION - EXPERIENCE IN 76 CONSECUTIVE PATIENTS [J].
KEREIAKES, DJ ;
SELMON, MR ;
MCAULEY, BJ ;
MCAULEY, DB ;
SHEEHAN, DJ ;
SIMPSON, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (03) :526-533
[9]  
KEREIAKES DJ, 1985, J AM COLL CARDIOL, V74, P292
[10]  
KOBER G, 1985, Z KARDIOL, V74, P309