AORTOILIAC IMAGING BY PROJECTIVE PHASE SENSITIVE MR ANGIOGRAPHY - EFFECTS OF TRIGGERING AND TIMING OF DATA ACQUISITION ON IMAGE QUALITY

被引:12
作者
LANZER, P
MCKIBBIN, W
BOHNING, D
THORN, B
GROSS, G
CRANNEY, G
NANDA, N
POHOST, G
机构
[1] University of Alabama at Birmingham, Department of Medicine, Division of Cardiovascular Disease, Birmingham
[2] University of Alabama at Birmingham, Department of Surgery, Division of Vascular Surgery, Birmingham
关键词
Aortoiliac vascular imaging; Phase imaging; Projective magnetic resonance angiography;
D O I
10.1016/0730-725X(90)90243-U
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the ability of projective phase sensitive magnetic resonance (MR) angiography to visualize the aortoiliac vascular segment, and to determine the effects of triggering and timing of data acquisition on image quality, we studied 18 healthy volunteers, mean age 33.3 ± 11 years, by color Doppler imaging and by MR angiography. MR angiography was performed at 1.5 T using a flow-adjustable gradient-echo (FLAG) sequence operated in both ECG-triggered and non-triggered acquisition modes. The images were graded in a blinded fashion by two independent observers. The data were analyzed using Pearson's chi-square analysis. Eighteen triggered time-resolved and 17 non-triggered, time-averaged MR angiograms consisting of 252 and 17 angiographic images, (AI) respectively, were analyzed. In the triggered mode 69 (27.4%) AI and in the non-triggered mode 2 (11.8%) AI were diagnostic. At least one triggered diagnostic AI was obtained in each subject. The image grades were not statistically different between observers (kappa = 0.6686). In the triggered mode diagnostic images were acquired within ± 90 msec of the peak systolic flow velocity determined by Doppler. The proportion of diagnostic images in the triggered mode was highest (73.3%) within a 30-msec interval before the peak flow. In healthy subjects the aortoiliac segment is reliably visualized by FLAG MR angiography. The optimum results are achieved using the triggered acquisition mode and timing acquisition to the initial 180 msec of the abdominal aortic systolic flow pulse. © 1990.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 22 条
  • [1] Lanzer, Botvinick, Schiller, Crooks, Arakawa, Kaufman, Davis, Hertkens, Cardiac imaging using gated magnetic resonance, Radiology, 150, pp. 121-127, (1984)
  • [2] Nishimura, Macovski, Pauly, Magnetic resonance angiography, IEEE Transactions on Medical Imaging, 1001-1005, pp. 140-151, (1986)
  • [3] Dixon, Du, Faul, Gado, Rossnick, Projection angiograms of blood labeled by adiabatic fast passage, Magn. Res. Med., 3, pp. 454-462, (1986)
  • [4] Moran, A flow velocity zeugmatographic interlace for NMR imaging in humans, Magn. Reson. Imaging, 1, pp. 197-203, (1982)
  • [5] Gullberg, Wehrli, Shimakawa, Simmons, MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections, Radiology, 165, pp. 241-246, (1987)
  • [6] Dumoulin, Hart, Magnetic resonance angiography, Radiology, 161, pp. 717-720, (1986)
  • [7] Dumoulin, Souza, Hart, Rapid scan magnetic resonance angiography, Magn. Res. Med., 5, pp. 238-245, (1987)
  • [8] Dumoulin, Souza, Walker, Yoshitome, Time-resolved magnetic resonance angiography, Magn. Res. Med., 6, pp. 275-286, (1988)
  • [9] Dumoulin, Souza, Fung, Multiecho magnetic resonance angiography, Magn. Res. Med., 5, pp. 47-57, (1987)
  • [10] Dumoulin, Souza, Walker, Wagle, Three-dimensional phase contrast angiography, Magn. Res. Med., 9, pp. 139-149, (1989)