JET SEPARATOR MEMBRANE INTRODUCTION MASS-SPECTROMETRY FOR ONLINE QUANTITATION OF VOLATILE ORGANIC-COMPOUNDS IN AQUEOUS-SOLUTIONS

被引:48
作者
DEJARME, LE
BAUER, SJ
COOKS, RG
LAURITSEN, FR
KOTIAHO, T
GRAF, T
机构
[1] PURDUE UNIV,DEPT CHEM,W LAFAYETTE,IN 47907
[2] ODENSE UNIV,INST BIOKEM,DK-5330 ODENSE,DENMARK
关键词
D O I
10.1002/rcm.1290071015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new technique is described for the direct detection of volatile organic compounds present in aqueous solutions at levels in the parts per trillion range. The sample is enriched in analyte in two consecutive stages; one utilizes a semi-permeable membrane interface and the other a jet separator. The analyte solution is sampled as it flows coaxially over a semi-permeable capillary membrane, the interior of which is continuously purged by helium. The permeate is pneumatically transported to the mass spectrometer via a jet separator, which is used to remove excess helium and water from the analyte vapor stream. Data are reported for two instruments; in one the membrane/jet separator system is interfaced to a single quadrupole mass spectrometer via a custom-built metal jet separator with a variable capillary gap. In the second, an ion-trap mass spectrometer is used in conjunction with a conventional fixed-gap quartz jet separator. Typical analyte response times are 2-5 min at ambient temperature, and flow injection methods are used for sample delivery. Direct comparisons, made under identical instrumental conditions, show that the jet separator system displays even lower detection limits than a conventional direct-insertion membrane probe. Detection limits in the range 30 parts per trillion to a few parts per billion are observed for selected volatile organic compounds and the response is linear over 3 orders of magnitude.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 31 条
[1]   PERFORMANCE OF AN ION-TRAP MASS-SPECTROMETER MODIFIED TO ACCEPT A DIRECT INSERTION MEMBRANE PROBE IN ANALYSIS OF LOW-LEVEL POLLUTANTS IN WATER [J].
BAUER, SJ ;
COOKS, RG .
TALANTA, 1993, 40 (07) :1031-1039
[2]  
Bier M. E., 1989, US Pat., Patent No. 4791292
[3]   MEMBRANE INTERFACE FOR SELECTIVE INTRODUCTION OF VOLATILE COMPOUNDS DIRECTLY INTO THE IONIZATION-CHAMBER OF A MASS-SPECTROMETER [J].
BIER, ME ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :597-601
[4]   CONTINUOUS MEASUREMENT OF WATER IN ORGANIC SOLUTION BY MEMBRANE-INLET MASS-SPECTROMETRY [J].
BOHATKA, S ;
DEGN, H .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (10) :433-436
[5]   GAS CONCENTRATION DETERMINATION IN FERMENTERS WITH QUADRUPOLE MASS-SPECTROMETER [J].
BOHATKA, S ;
LANGER, G ;
SZILAGYI, J ;
BERECZ, I .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 48 (FEB) :277-280
[6]   INVIVO MASS-SPECTROMETRIC DETERMINATION OF ORGANIC-COMPOUNDS IN BLOOD WITH A MEMBRANE PROBE [J].
BRODBELT, JS ;
COOKS, RG ;
TOU, JC ;
KALLOS, GJ ;
DRYZGA, MD .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :454-458
[7]   FIELD SCREENING OF HAZARDOUS-WASTE SITES .1. [J].
CHUDYK, W .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (05) :504-507
[8]  
COOKS RG, 1992, ACS S SER, V508
[9]   ANALYTICAL-CHEMISTRY FOR ENVIRONMENTAL SCIENCES - A QUESTION OF CONFIDENCE [J].
DELIA, CF ;
SANDERS, JG ;
CAPONE, DG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (07) :768-774
[10]   HOW TO MONITOR ORGANICS IN AIR [J].
EVANS, JE ;
ARNOLD, JT .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1975, 9 (13) :1134-1138