BLIND DECONVOLUTION OF QUANTUM-LIMITED INCOHERENT IMAGERY - MAXIMUM-LIKELIHOOD APPROACH

被引:155
作者
HOLMES, TJ
机构
[1] Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY
关键词
D O I
10.1364/JOSAA.9.001052
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Previous research presented by the author and others into maximum-likelihood image restoration for incoherent imagery is extended to consider problems of blind deconvolution in which the impulse response of the system is assumed to be unknown. Potential applications that motivate this study are wide-field and confocal fluorescence microscopy, although applications in astronomy and infrared imaging are foreseen as well. The methodology incorporates the iterative expectation-maximization algorithm. Although the precise impulse response is assumed to be unknown, some prior knowledge about characteristics of the impulse response is used. In preliminary simulation studies that are presented, the circular symmetry and the band-limited nature of the impulse response are used as such. These simulations demonstrate the potential utility and present limitations of these methods.
引用
收藏
页码:1052 / 1061
页数:10
相关论文
共 60 条
[1]  
AGARD DA, 1989, METHOD CELL BIOL, V30, P353
[2]  
AGARD DA, 1984, ANNU REV BIOPHYS BIO, V13, P191
[3]  
AIKENS RS, 1989, METHOD CELL BIOL, V29, P291
[4]  
Arfken G., 1985, MATH METHODS PHYS, V3rd, P957
[5]   ITERATIVE BLIND DECONVOLUTION METHOD AND ITS APPLICATIONS [J].
AYERS, GR ;
DAINTY, JC .
OPTICS LETTERS, 1988, 13 (07) :547-549
[6]   SOME IMPLICATIONS OF ZERO SHEETS FOR BLIND DECONVOLUTION AND PHASE RETRIEVAL [J].
BATES, RHT ;
QUEK, BK ;
PARKER, CR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (03) :468-479
[7]  
BRACKENHOFF GJ, 1989, HDB BIOL CONFOCAL MI, P79
[8]  
CARRINGTON WA, 1990, P SOC PHOTO-OPT INS, V1205, P72, DOI 10.1117/12.17785
[9]  
Castleman K. R., 1979, DIGITAL IMAGE PROCES
[10]   AN EVALUATION OF MAXIMUM-LIKELIHOOD RECONSTRUCTION FOR SPECT [J].
CHORNOBOY, ES ;
CHEN, CJ ;
MILLER, MI ;
MILLER, TR ;
SNYDER, DL .