INTRAVASCULAR ULTRASOUND IMAGING OF ARTERIAL-WALL ARCHITECTURE

被引:14
作者
GE, J
ERBEL, R
GORGE, G
GERBER, T
BRENNECKE, R
SEIDEL, I
REICHERT, T
MEYER, J
机构
[1] Second Medical Clinic, Johannes Gutenberg-University, Mainz
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 1992年 / 9卷 / 05期
关键词
INTRAVASCULAR ULTRASOUND; ARTERIAL WALL ARCHITECTURE; AORTIC DISSECTION; ULTRASOUND;
D O I
10.1111/j.1540-8175.1992.tb00490.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) is a promising new technique for assessing vascular morphology and structure. Controversy exists whether the three-layer appearance of the arterial wall correctly reflects the histologic structures of the intima, media, and adventitia. We performed an experimental study to clarify the three-layer appearance. The vessel wall architecture was analyzed by IVUS on eight different kinds of plastic cylinders, 24 normal blood vessels from pigs, and 59 human arterial segments. A distinct three-layer appearance was observed on all the plastic cylinders when the ultrasound beam was perpendicular to the wall. A three-layer appearance was also seen in the arterial wall, in the muscular (iliac, femoral artery) and elastic types (aorta), when the echo beam was perpendicular to the vessel wall. The three-layer pattern was even observed on the arterial wall when the intima was removed. Furthermore, the removed intima itself provided a three-layer image. Histologic examination showed that there was no correspondence between the IVUS three-layer appearance and the intima, media, and adventitia. Moreover, we also performed IVUS on nine patients who suffered from aortic dissection. Intravascular ultrasonic visualization of the dissected intima showed a distinct three-layer pattern. The pattern disappeared when: (1) the echo beam was not perpendicular to the vessel wall; (2) there was connective tissue around the vessel wall; (3) there was arterial wall calcification; or (4) the vessel wall was too thick or the distance between the ultrasound transducer and the vessel wall was too large. We conclude that the three-layer pattern in IVUS images seems to not represent the histologic intima, media, and adventitia, but results from the reflection of echo beam at the border zones.
引用
收藏
页码:475 / 483
页数:9
相关论文
共 21 条
  • [1] Grondin CM, Dyrada I, Pasternac A, Et al., Discrepancies between cineangiographic and postmortem findings in patients with coronary artery disease and recent myocardial revascularization, Circulation, 49, (1974)
  • [2] Kamp HG, Evans H, Elliot WC, Et al., Diagnostic accuracy of selective coronary arteriography, Circulation, 36, (1974)
  • [3] Zir LM, Miller SW, Dinsmore RE, Et al., Interobserver variability in coronary angiography, Circulation, 53, (1976)
  • [4] White CW, Wright CB, Doty DB, Et al., Does visual interpretation of the coronary angiograms predict the physiologic importance of the coronary stenosis?, N Engl J Med, 310, (1984)
  • [5] Pandian NG, Kreis A, Brockway B, Et al., Ultrasound angioscopy: Real‐time, two‐dimensional, intraluminal ultrasound imaging of blood vessels, Am J Cardiol, 62, (1988)
  • [6] Ge J, Erbel R, Seidel I, Et al., Experimented Überprüfung der Genauigkeit und Sicherheit des intraluminalen Ultraschalls, Z Kardiol, 80, (1991)
  • [7] Hodgson JM, Graham SP, Sheehan H, Et al., Percutaneous intracoronary ultrasound imaging: Initial applications in patients, Echocardiography, 7, (1990)
  • [8] Tobis JM, Mallery JA, Mahon D, Et al., Intravascular ultrasound imaging: A new method for guiding interventional vascular procedures, Echocardiography, 7, (1990)
  • [9] Nissen SE, Grines CL, Gurley JC, Et al., Application of a new phased‐array ultrasound imaging catheter in the assessment of vascular dimensions in vivo comparison to cineangiography, Circulation, 81, (1990)
  • [10] Pandian NG, Kreis A, O'Donell T, Intravascular ultrasound estimation of arterial stenosis, J Am Soc Echocardiogr, 2, (1989)