REPRODUCIBILITY OF DOPPLER ULTRASOUND MEASUREMENT OF RESISTANCE INDEX IN RENAL-ALLOGRAFTS

被引:26
作者
LONDON, NJ
ALDOORI, MI
LODGE, VG
BATES, JA
IRVING, HC
GILES, GR
机构
[1] ST JAMES UNIV HOSP,DEPT CLIN MED,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
[2] ST JAMES UNIV HOSP,DEPT RADIOL,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
关键词
D O I
10.1259/0007-1285-66-786-510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years measurements of arterial blood flow in the renal allograft have been studied in an attempt to provide a non-invasive method of diagnosing and monitoring post-transplant renal dysfunction. Many studies have involved measurement of the resistance index (RI) of arterial blood flow. Although the reproducibility of the technique has been studied in other areas of application, no such studies have been performed on the renal allograft. In this study we attempted to evaluate the reproducibility of the measurement of the RI of the interlobar artery in the renal allograft. 18 renal allograft recipients with stable functioning grafts were studied twice by each of two experienced sonographers using a colour-coded duplex Doppler ultrasound scanner, in order to determine the intraobserver and interobserver variability in the measurement of RI of the interlobar arteries in the allograft. Variability was small and although interobserver variability exceeded intraobserver variability, both were within repeatability limits adopted by the British Standards Institution. The results suggest that measurement of the RI of the interlobar artery of renal allografts is repeatable and reproducible when performed by experienced operators.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 17 条
  • [1] ANALYSIS OF THE ARTERIAL BLOOD-FLOW PATTERNS OF NORMAL AND ALLOGRAFTED KIDNEYS BY THE DIRECTIONAL ULTRASONIC DOPPLER TECHNIQUE
    ARIMA, M
    ISHIBASHI, M
    USAMI, M
    SAGAWA, S
    MIZUTANI, S
    SONODA, T
    ICHIKAWA, S
    IHARA, H
    NAGANO, S
    [J]. JOURNAL OF UROLOGY, 1979, 122 (05) : 587 - 591
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] DAVIES JA, 1990, OBSTET GYNECOL, V76, P366
  • [4] EVANS C, 1989, TRANSPLANT P, V21, P1897
  • [5] DUPLEX DOPPLER SONOGRAPHY OF RENAL-TRANSPLANTS - LACK OF SENSITIVITY AND SPECIFICITY IN ESTABLISHING PATHOLOGIC DIAGNOSIS
    GENKINS, SM
    SANFILIPPO, FP
    CARROLL, BA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) : 535 - 539
  • [6] LONDON NJ, 1992, CLIN TRANSPLANT, V6, P407
  • [7] MARCHAL G, 1989, TRANSPLANT P, V21, P1893
  • [8] MOORTHY B, 1989, ROY ARMY MED CORPS, V135, P131
  • [9] INTERNAL CAROTID-ARTERY STENOSIS - ACCURACY AND REPRODUCIBILITY OF COLOR-DOPPLER-ASSISTED DUPLEX IMAGING
    POLAK, JF
    DOBKIN, GR
    OLEARY, DH
    WANG, AM
    CUTLER, SS
    [J]. RADIOLOGY, 1989, 173 (03) : 793 - 798
  • [10] POURCELOT L, 1975, VELOCIMETRIC ULTRASO, V34, P213