摘要
Comparison of the radiation exposure during CT quoted in the literature shows considerable variation; this depends on differences in apparatus, methods of examination and measurements. A systematic investigation into radiation dose during CT is therefore necessary to obtain accurate radiation doses during various examinations in order to balance risks against usefulness. The present paper deals with the radiation dose received by the patient during examinations of the cerebrum, neck, thorax, upper and lower abdomen and pelvis, using standard and spiral CT techniques. Organ doses for all organs at risk, surface dose, total body dose and dose profiles along the body axis for each type of examination have been established, which will allow the user to evaluate radiation dose.
引用
收藏
页码:3 / 11
页数:9
相关论文
共 24 条
[1]  
BRUGESS AE, 1985, J COMPUT ASSIST TOMO, V9, P926
[2]   AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY [J].
CONWAY, BJ ;
MCCROHAN, JL ;
ANTONSEN, RG ;
RUETER, FG ;
SLAYTON, RJ ;
SULEIMAN, OH .
RADIOLOGY, 1992, 184 (01) :135-140
[3]   NATIONAL CT USE AND RADIATION EXPOSURE - UNITED-STATES 1983 [J].
EVENS, RG ;
METTLER, FA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (05) :1077-1081
[4]   SOMATIC RADIATION RISK DURING ANGIOGRAPHY [J].
EWEN, K ;
FIEBACH, BJO ;
HINZ, A .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1982, 137 (06) :704-706
[5]  
FAULKNER K, 1987, ACTA RADIOL, V28, P483
[6]  
Kalender W A, 1990, Rontgenpraxis, V43, P323
[7]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[8]   PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING [J].
KALENDER, WA ;
POLACIN, A .
MEDICAL PHYSICS, 1991, 18 (05) :910-915
[9]  
Kronholz H L, 1983, Rofo, V138, P444, DOI 10.1055/s-2008-1055758
[10]   AVERAGE RADIATION-DOSES IN A STANDARD HEAD EXAMINATION FOR 250-CT SYSTEMS [J].
MCCROHAN, JL ;
PATTERSON, JF ;
GAGNE, RM ;
GOLDSTEIN, HA .
RADIOLOGY, 1987, 163 (01) :263-268