The fabrication and performance of graphite-Teflon-enzyme electrodes are described. The new bulk-modified composite enzyme electrodes couple the advantages of renewable (polishable) surfaces, mechanical rigidity, fast response, and favorable signal-to-noise characteristics. The new fabrication strategy is illustrated for the immobilization of horseradish peroxidase and glucose oxidase, in connection with measurements of peroxide species and glucose, respectively. The incorporation of a ferrocene mediator to yield a reagentless device is also illustrated. Flow injection measurements of hydrogen peroxide with the graphite-Teflon-peroxidase detector are carried out at 120 samples/hour, to yield a detection limit of 2.5 x 10(-6) M and a relative standard deviation of 2%. Applicability to organic-phase biosensing is illustrated.
引用
收藏
页码:575 / 579
页数:5
相关论文
共 11 条
[1]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[2]   VOLTAMMETRIC CHARACTERIZATION OF A GRAPHITE-TEFLON ELECTRODE [J].
KLATT, LN ;
CONNELL, DR ;
ADAMS, RE ;
HONIGBERG, IL ;
PRICE, JC .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2470-2472
[3]   ORGANIC-PHASE ENZYME ELECTRODES [J].
SAINI, S ;
HALL, GF ;
DOWNS, MEA ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :1-15
[4]   LCEC DETECTOR WITH GRAPHITE-TEFLON ELECTODE [J].
SHAH, MH ;
HONIGBERG, IL .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1983, 16 (15) :1149-1163
[5]   COMPOSITE ELECTRODES FOR ELECTROANALYSIS - PRINCIPLES AND APPLICATIONS [J].
TALLMAN, DE ;
PETERSEN, SL .
ELECTROANALYSIS, 1990, 2 (07) :499-510
[6]  
Turner A., 1987, BIOSENSORS FUNDAMENT
[7]   MODIFIED ELECTRODES FOR ELECTROCHEMICAL SENSORS [J].
WANG, J .
ELECTROANALYSIS, 1991, 3 (4-5) :255-259
[8]   ORGANIC-PHASE ENZYMATIC ASSAYS WITH ULTRAMICROELECTRODES [J].
WANG, J ;
WU, LH ;
ANGNES, L .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2993-2994
[9]   POLISHABLE AND ROBUST BIOLOGICAL ELECTRODE SURFACES [J].
WANG, J ;
VARUGHESE, K .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :318-320
[10]   MIXED FERROCENE GLUCOSE-OXIDASE CARBON-PASTE ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
WANG, J ;
WU, LH ;
LU, ZL ;
LI, RL ;
SANCHEZ, J .
ANALYTICA CHIMICA ACTA, 1990, 228 (02) :251-257