Stainless-steel wire, titanium mesh and perforated titanium sheets and methylmethacrylate were used in conjunction with autogenous iliac-bone grafts to provide immediate stability in difficult or long posterior cervical fusions in 11 patients with rheumatoid arthritis, who were followed for 3-12.5 yr. Two surgical techniques, using methylmethacrylate and metal supplementation of a traditional posterior cervical arthrodesis, are described. One technique includes the occiput, while the other consists of a long posterior fusion that excludes the occiput. In 10 of the 11 patients, permanent radiographic stability was maintained as well as a significant reduction of pain and resolution of neural dysfunction. In the 11th patient a cervical subluxation developed at the distal end of the rigidly fused segment, and eventually the patient died. Four patients who were seen early in the series had wound dehiscences, 2 of which were infected. Subsequently the methacrylate-metal composite was reduced in volume, and this problem did not recur. This technique provided immediate internal splinting and avoided bulky external-fixation devices. It was most useful in fusions of the occiput to the upper part of the cervical spine, in long posterior cervical arthrodeses, and for the repair of pseudarthroses when traditional arthrodesis techniques failed.
引用
收藏
页码:1045 / 1050
页数:6
相关论文
共 14 条
[1]   ALTERNATE METHOD FOR POSTERIOR FIXATION IN ANTERIOR AND INFERIOR ATLANTO-AXIAL DISLOCATION [J].
ALTHOFF, B ;
GOLDIE, IF .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 93 (03) :243-248
[2]   ATLANTO-AXIAL FUSION IN RHEUMATOID-ARTHRITIS - NEW METHOD OF FIXATION WITH WIRE AND BONE CEMENT [J].
BRATTSTROM, H ;
GRANHOLM, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1976, 47 (06) :619-628
[3]  
CLARK C R, 1980, Orthopaedic Transactions, V4, P41
[4]  
CRELLIN R Q, 1970, Journal of Bone and Joint Surgery British Volume, V52, P244
[5]   METHYLMETHACRYLATE AS AN ADJUNCT IN SPINAL INSTRUMENTATION [J].
HERRON, LD ;
DAWSON, EG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :866-868
[6]   ACRYLIC FIXATION OF ATLANTO-AXIAL DISLOCATIONS - TECHNICAL NOTE [J].
KELLY, DL ;
ALEXANDER, E ;
SMITH, JM ;
DAVIS, CH .
JOURNAL OF NEUROSURGERY, 1972, 36 (03) :366-+
[7]  
MARTEL W, 1961, AMER J ROENTGENOL RA, V86, P223
[8]  
PELLICCI P M, 1980, Orthopaedic Transactions, V4, P311
[9]  
RANA NA, 1973, J BONE JOINT SURG AM, VA 55, P1304
[10]   CERVICAL-SPINE FUSION IN RHEUMATOID-ARTHRITIS [J].
RANAWAT, CS ;
OLEARY, P ;
PELLICCI, P ;
TSAIRIS, P ;
MARCHISELLO, P ;
DORR, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (07) :1003-1010