LINEAR-GEOMETRY ELECTRIC-FIELD PROBE FOR DC CORONA MEASUREMENTS

被引:8
作者
BOUZIANE, A
HARTMANN, G
HIDAKA, K
TAPLAMACIOGLU, MC
WATERS, RT
机构
[1] CNRS,PHYS DECHARGES LAB,F-91192 GIF SUR YVETTE,FRANCE
[2] UNIV TOKYO,BUNKYO KU,TOKYO 113,JAPAN
关键词
CORONA MEASUREMENTS; GAS DISCHARGES;
D O I
10.1049/ip-smt:19941012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
The technique for DC corona field measurement by means of a biased-current probe has been adapted to a linear geometry for use in corona discharges. Calibration of the probe requires account to be taken of the finite length of the collector. Design parameters are given, and calibration is obtained by means of analytical computation which simulates the biased probe by a system of inclined planes, and by a three dimensional charge simulation computer program.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 7 条
[1]
BOUZIANE A, 1989, 6TH INT S HIGH VOLT
[2]
BOUZIANE A, 1994, IN PRESS IEE P SCI M
[3]
STATIC PROBE FOR ELECTROSTATIC-FIELD MEASUREMENT IN THE PRESENCE OF SPACE-CHARGE [J].
SELIM, EO ;
WATERS, RT .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1980, 16 (03) :458-463
[4]
FIELD-FILTER PROBES AND THE MEASUREMENT OF ALTERNATING-CURRENT CORONA [J].
STARK, WB ;
SELIM, EO ;
WATERS, RT .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1980, 16 (03) :464-472
[5]
TASSICKER OJ, 1974, P I ELECTR ENG, V21, P213
[6]
CYLINDRICAL ELECTROSTATIC FLUXMETER FOR CORONA STUDIES [J].
WATERS, RT .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1972, 5 (05) :475-&
[7]
STRUCTURE OF IMPULSE CORONA IN A ROD/PLANE GAP .1. POSITIVE CORONA [J].
WATERS, RT ;
RICKARD, TES ;
STARK, WB .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 315 (1520) :1-&