QUANTITATIVE COLOR FLOW IMAGING TO MEASURE THE 2-DIMENSIONAL DISTRIBUTION OF BLOOD-FLOW VELOCITY AND THE FLOW-RATE

被引:8
作者
KITABATAKE, A
TANOUCHI, J
YOSHIDA, Y
MASUYAMA, T
UEMATSU, M
KAMADA, T
机构
[1] The First Department of Medicine, Osaka University School of Medicine, Osaka
来源
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION | 1990年 / 54卷 / 03期
关键词
color; Doppler; flow; Flow; imaging; profile; rate; velocity;
D O I
10.1253/jcj.54.304
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
A quantitative Doppler color flow imaging was employed to measure the twodimensional distribution of blood flow velocity and flow rate in a large vessel. Regional blood flow velocity was determined by converting the color intensity at the respective pixel into corresponding flow velocity and correcting the flow velocity for spatial ultrasound beam incident angle. Instantaneous flow rate was determined precisely from the image of velocity distribution on the cross-section of the flow tract in a steady flow model circuit. In clinical application, the differences in phasic changes in two-dimensional velocity distribution in the ascending aorta, between normal subjects and the patient with aortic regurgitation, were clearly depicted. The quantitative color flow imaging may have great potential to determine noninvasively and real-timely the two-dimensional distribution of flow velocity as well as flow rate in a large vessel. © 1990, The Japanese Circulation Society. All rights reserved.
引用
收藏
页码:304 / 308
页数:5
相关论文
共 9 条
[1]   A DOPPLER-2-DIMENSIONAL ECHOCARDIOGRAPHIC METHOD FOR QUANTITATION OF MITRAL REGURGITATION [J].
ASCAH, KJ ;
STEWART, WJ ;
LENG, JA ;
GUERRERO, JL ;
NEWELL, JB ;
GILLAM, LD ;
WEYMAN, AE .
CIRCULATION, 1985, 72 (02) :377-383
[2]  
KITABATAKE A, 1987, MED PROG TECHNOL, V12, P87
[3]   THE VELOCITY PROFILE IN THE CANINE ASCENDING AORTA AND ITS EFFECTS ON THE ACCURACY OF PULSED DOPPLER DETERMINATIONS OF MEAN BLOOD VELOCITY [J].
LUCAS, CL ;
KEAGY, BA ;
HSIAO, HS ;
JOHNSON, TA ;
HENRY, GW ;
WILCOX, BR .
CARDIOVASCULAR RESEARCH, 1984, 18 (05) :282-293
[4]   CLINICAL-APPLICATIONS OF A NEW TYPE OF REAL-TIME TWO-DIMENSIONAL DOPPLER FLOW IMAGING-SYSTEM [J].
MIYATAKE, K ;
OKAMOTO, M ;
KINOSHITA, N ;
IZUMI, S ;
OWA, M ;
TAKAO, S ;
SAKAKIBARA, H ;
NIMURA, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (07) :857-868
[5]   3-DIMENSIONAL VISUALIZATION OF VELOCITY PROFILES IN THE ASCENDING AORTA IN HUMANS - A COMPARATIVE-STUDY AMONG NORMAL AORTIC VALVES, ST-JUDE MEDICAL AND STARR-EDWARDS SILASTIC BALL VALVES [J].
PAULSEN, PK ;
HASENKAM, JM ;
STODKILDEJORGENSEN, H ;
ALBRECHTSEN, O .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (04) :277-292
[6]   BLOOD VELOCITY DISTRIBUTION IN THE HUMAN ASCENDING AORTA [J].
SEGADAL, L ;
MATRE, K .
CIRCULATION, 1987, 76 (01) :90-100
[7]   FLOW IN ENTRANCE OF AORTA [J].
SINGH, MP ;
SINHA, PC ;
AGGARWAL, M .
JOURNAL OF FLUID MECHANICS, 1978, 87 (JUL) :97-120
[8]   DETECTION, LOCALIZATION, AND QUANTITATION OF BIOPROSTHETIC MITRAL-VALVE REGURGITATION - AN INVITRO TWO-DIMENSIONAL COLOR-DOPPLER FLOW-MAPPING STUDY [J].
VANDENBERG, BF ;
DELLSPERGER, KC ;
CHANDRAN, KB ;
KERBER, RE .
CIRCULATION, 1988, 78 (03) :529-538
[9]  
YOSHIDA Y, UNPUB QUANTIFICATION