WINDOW TRANSMISSION MONITORING AND CLEANING SCHEMES USED WITH THE LIGHT DETECTION AND RANGING THOMSON SCATTERING DIAGNOSTIC ON THE JET TOKAMAK

被引:17
作者
BROWN, BW
GOWERS, CW
NIELSEN, P
SCHUNKE, B
机构
[1] JET Joint Undertaking, Abingdon, Oxon
关键词
Optical radar;
D O I
10.1063/1.1145534
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Light Detection and Ranging Thomson scattering diagnostic on the JET tokamak makes routine measurements of the plasma electron temperature and density profiles. During JET operations the windows used for scattered light collection gradually become coated with deposits due to the plasma erosion of the wall. The consequent loss in transmission can affect the electron density and also the electron temperature measurement. This paper describes both the method adopted to monitor the change in transmission due to the gradual build up of deposits and the application of laser window cleaning to counteract it. © 1995 American Institute of Physics.
引用
收藏
页码:3077 / 3078
页数:2
相关论文
共 3 条
[1]  
BROWN BW, JETTN9103
[3]   THE LIDAR THOMSON SCATTERING DIAGNOSTIC ON JET [J].
SALZMANN, H ;
BUNDGAARD, J ;
GADD, A ;
GOWERS, C ;
HANSEN, KB ;
HIRSCH, K ;
NIELSEN, P ;
REED, K ;
SCHRODTER, C ;
WEISBERG, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08) :1451-1456