FIELD-INDUCED DISINTEGRATION OF GLYCEROL SOLUTIONS UNDER VACUUM AND ATMOSPHERIC-PRESSURE CONDITIONS STUDIED BY OPTICAL MICROSCOPY AND MASS-SPECTROMETRY

被引:16
作者
LUTTGENS, U
DULCKS, T
ROLLGEN, FW
机构
[1] Institut für Physikalische und Theoretische Chemie, Universität Bonn, W-5300 Bonn 1
关键词
D O I
10.1016/0039-6028(92)91021-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The ion formation in both electrohydrodynamic (EH) and electrospray (ES) mass spectrometry (MS) is based on the electrohydrodynamic disintegration of sample solutions which are passed through a capillary biased at high potential. Vacuum is applied in EH and atmospheric pressure in ES MS. For glycerol applied as solvent in EH MS optical studies of its disintegration behavior revealed a change from axial spray modes to a rim emission mode in vacuum and a change from axial spray modes to a droplet ejection mode at atmospheric pressure conditions with increasing potential. EH MS investigations of the ion emission from only one or a few emission sites at the rim of the capillary showed a pulsed ion emission whose frequency increased with applied potential. The pulsed ion emission is attributed to an imbalance between the supply and loss of liquid at an emission site. By lowering the surface tension of glycerol with dodecyl sulfate sodium salt an increase of mass spectral ion intensity by more than one order of magnitude could be observed.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 21 条
[1]   ON THE WORKING CHARACTERISTICS OF AN ION-SOURCE WITH ELECTROHYDRODYNAMIC INTRODUCTION OF LIQUIDS INTO THE MASS-SPECTROMETER [J].
ALEXANDROV, ML ;
GALL, LN ;
KRASNOV, NV ;
NIKOLAEV, VI ;
PAVLENKO, VA ;
SHKUROV, VA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 54 (1-2) :231-235
[2]   EMISSION CURRENT DEPENDENCE IN THE TIME AND ANGLE NOISE SPECTRA OF GALLIUM LIQUID-METAL ION SOURCES [J].
BARR, DL ;
BROWN, WL ;
THOMSON, DJ .
JOURNAL DE PHYSIQUE, 1988, 49 (C-6) :177-182
[3]   ELECTROHYDRODYNAMIC MASS-SPECTROMETRY [J].
COOK, KD .
MASS SPECTROMETRY REVIEWS, 1986, 5 (04) :467-519
[4]  
Dudnikov V. G., 1985, Soviet Physics - Technical Physics, V30, P462
[5]   ELECTROHYDRODYNAMIC ION-SOURCE FOR MASS-SPECTROMETRY OF LIQUIDS [J].
EVANS, CA ;
HENDRICKS, CD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (10) :1527-+
[6]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[7]   ELECTRODYNAMIC EFFECTS IN FIELD DESORPTION MASS-SPECTROMETRY [J].
GIESSMANN, U ;
ROLLGEN, FW .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1981, 38 (2-3) :267-279
[8]   FACTORS INFLUENCING ELECTRICALLY SPRAYED LIQUIDS [J].
HOGAN, JJ ;
CARSON, RS ;
SCHNEIDER, JM ;
HENDRICKS, CD .
AIAA JOURNAL, 1964, 2 (08) :1460-1461
[9]  
Hornsey R, 1989, J PHYS, V50, DOI 10.1051/jphyscol:1989834
[10]  
KINGHAM DR, 1984, VACUUM, V34, P945