COMPARISON OF TECHNIQUES FOR MINIMIZING INTERFERENCE OF BILIRUBIN ON SERUM CREATININE DETERMINED BY THE KINETIC JAFFE REACTION

被引:14
作者
LOLEKHA, PH
SRITONG, N
机构
[1] Division of General Clinical Chemistry, Department of Pathology, Ramathibodi Hospital, Mahidol University, Bangkok
关键词
BILIRUBIN INTERFERENCE; SERUM CREATININE; KINETIC JAFFE REACTION;
D O I
10.1002/jcla.1860080609
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 [基础医学];
摘要
This study compared the effect of sodium dodecyl-sulfate, potassium ferricyanide, and preincubation technique to continuous-flow analysis and prior deproteinization to correct the negative interference of bilirubin on serum creatinine found by the kinetic Jaffe reaction. Bilirubin increased to 684 mu mol/L did not interfere with serum creatinine measured by the methods incorporated with dialysis or deproteinization. Trichloroacetic-acid was the best protein precipitant. The reagent incorporated with sodium dodecyl sulfate was more appropriate to minimize bilirubin interference than reagent containing potassium ferricyanide. An increase in potassium ferricyanide concentration resulted in false positive creatinine values. Incorporation of both SDS and potassium ferricyanide in the reagent did not help in minimizing the bilirubin interference over use of each chemical alone. The 10 minutes of preincubation of the sample with alkaline buffer incorporating with either SDS or potassium ferricyanide before starting the Jaffe reaction was the appropriate way to overcome unconjugated bilirubin interference at a level of 342.0 mu mol/L. However, the technique did not work uniformly with icteric patient sera containing conjugated, unconjugated, and delta bilirubin. This is a challenging problem that remains to be solved by the clinical chemist. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:391 / 399
页数:9
相关论文
共 27 条
[1]
BACON BL, 1989, CLIN CHEM, V35, P360
[2]
BOWERS LD, 1980, CLIN CHEM, V26, P555
[3]
CREATININE ASSAY IN PRESENCE OR PROTEIN [J].
COOK, JGH .
CLINICA CHIMICA ACTA, 1971, 32 (03) :485-&
[4]
NEGATIVE INTERFERENCE IN A KINETIC JAFFE METHOD FOR SERUM CREATININE DETERMINATION [J].
CRUICKSHANK, AM ;
BALLANTYNE, FC ;
SHENKIN, A .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :112-113
[5]
DAUGHERTY NA, 1978, CLIN CHEM, V24, P392
[6]
DOUMAS BT, 1973, CLIN CHEM, V19, P984
[7]
FABINY DL, 1971, CLIN CHEM, V17, P696
[8]
FRANZINI C, 1991, CLIN CHEM, V37, P236
[9]
DETERMINATION OF SERUM CREATININE BY A DIRECT COLORIMETRIC METHOD [J].
HEINEGAR.D ;
TIDERSTR.G .
CLINICA CHIMICA ACTA, 1973, 43 (03) :305-310
[10]
HENRY RJ, 1964, CLIN CHEM PRINCIPLES, P160