GAS TRAPPING DURING HIGH-FREQUENCY POSITIVE PRESSURE VENTILATION USING CONVENTIONAL VENTILATORS

被引:59
作者
HIRD, M
GREENOUGH, A
GAMSU, H
机构
[1] Department of Child Health, King's College Hospital, London, Denmark Hill
关键词
gas trapping; neonatal ventilation; pancuronium; respiratory distress;
D O I
10.1016/0378-3782(90)90025-E
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Inspiratory and expiratory volumes were measured in 51 preterm infants with respiratory distress syndrome (RDS), when comparing two ventilator rates, 60 and 120 breaths/min. Gas trapping was not demonstrated at rates of 60, but in 11 infants at 120 breaths/min and this was more common in the paralysed infants and those more mature than 31 weeks gestational age (P < 0.05). The median change in functional residual capacity resulting from gas trapping was 3.8 ml/kg. We conclude rates of 120 breaths/min can be used in the majority of non-paralysed infants without gas trapping but should be avoided in paralysed infants more mature than 31 weeks. © 1990.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 6 条
[1]   PULMONARY INTERSTITIAL EMPHYSEMA [J].
GREENOUGH, A ;
DIXON, AK ;
ROBERTON, NRC .
ARCHIVES OF DISEASE IN CHILDHOOD, 1984, 59 (11) :1046-1051
[2]   HIGH-FREQUENCY VENTILATION IN THE NEONATAL-PERIOD [J].
GREENOUGH, A ;
MILNER, AD .
EUROPEAN JOURNAL OF PEDIATRICS, 1987, 146 (05) :446-449
[3]   COMPARISON OF DIFFERENT RATES OF ARTIFICIAL-VENTILATION IN PRETERM NEONATES WITH RESPIRATORY-DISTRESS SYNDROME [J].
GREENOUGH, A ;
POOL, J ;
GREENALL, F ;
MORLEY, C ;
GAMSU, H .
ACTA PAEDIATRICA SCANDINAVICA, 1987, 76 (05) :706-712
[4]  
GREENOUGH A, 1987, PEDIATR PULM, V3, P557
[5]   PROSPECTIVE CLINICAL COMPARISON OF 2 METHODS FOR MECHANICAL VENTILATION OF NEONATES - RAPID RATE AND SHORT INSPIRATORY TIME VERSUS SLOW RATE AND LONG INSPIRATORY TIME [J].
HEICHER, DA ;
KASTING, DS ;
HARROD, JR .
JOURNAL OF PEDIATRICS, 1981, 98 (06) :957-961