OBJECT AND DETECTOR SCATTER FUNCTION DEPENDENCE ON ENERGY AND POSITION IN HIGH-RESOLUTION PET

被引:24
作者
BENTOURKIA, M
MSAKI, P
CADORETTE, J
LECOMTE, R
机构
[1] Department of Nuclear Medicine and Radiobiology, University of Sherbrooke, Sherbrooke, Québec
基金
加拿大自然科学与工程研究理事会; 英国医学研究理事会;
关键词
D O I
10.1109/23.467732
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have shown in previous works that distinct non-stationary analytical scatter kernels can be extracted from line source measurements and used to independently subtract object scatter and subtract or restore detector scatter in high resolution PET. In this work, the dependence of the scatter components on energy threshold and source position was investigated. Line source measurements were acquired in multispectral mode using the Sherbrooke PET simulator. Scatter parameters were extracted from data summed in energy windows with a lower threshold varying from 129 keV to 516 keV in steps of 42 keV, and a fixed upper threshold of 644 keV. Decreasing the lower threshold from 344 keV to 129 keV increases the trues by only 25%, but increases object scatter by 136% and almost triples detector scatter. A gain in efficiency by a factor of 2 or more would result from recovering the latter by restoration in the broad window. The intensity and shape of the scatter functions for both object and detector are shown to have a significant dependence on energy and position. This dependence needs to be taken into account in the design of kernels for accurate scatter correction over a broad energy range.
引用
收藏
页码:1162 / 1167
页数:6
相关论文
共 18 条
[1]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[2]  
BENDRIEM B, 1993, 1993 IEEE NSS MIC, V3, P1779
[3]  
BENTOURKIA M, 1995, J NUCL MED, V36, P121
[4]   ENERGY-DEPENDENCE OF SCATTER COMPONENTS IN MULTISPECTRAL PET IMAGING [J].
BENTOURKIA, M ;
MSAKI, P ;
CADORETTE, J ;
LECOMTE, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :138-145
[5]  
BENTOURKIA M, IN PRESS J NUCL MED
[6]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[7]   TUNING OF AVALANCHE PHOTODIODE PET CAMERA [J].
CADORETTE, J ;
RODRIGUE, S ;
LECOMTE, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1062-1066
[8]   A POSITRON TOMOGRAPH WITH 600-BGO CRYSTALS AND 2.6 MM RESOLUTION [J].
DERENZO, SE ;
HUESMAN, RH ;
CAHOON, JL ;
GEYER, AB ;
MOSES, WW ;
UBER, DC ;
VULETICH, T ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :659-664
[9]  
GROOTOONK S, 1991, 1991 IEEE NUCL SCI S, V3, P1569
[10]  
HARRISON RL, 1991, 1991 IEEE NUCL SCI S, V3, P1700