AN APPROACH TO DETERMINE OBJECTIVELY MINIMUM HEMOGLOBIN STANDARDS FOR BLOOD-DONORS

被引:21
作者
ALI, AM
MCAVOY, AT
ALI, MAM
GOLDSMITH, CH
BLAJCHMAN, MA
机构
[1] ST JOSEPHS HOSP, HAMILTON L8N 1Y4, ONTARIO, CANADA
[2] MCMASTER UNIV, DEPT PATHOL, HAMILTON L8S 4L8, ONTARIO, CANADA
[3] MCMASTER UNIV, DEPT MED, HAMILTON L8S 4L8, ONTARIO, CANADA
[4] MCMASTER UNIV, DEPT CLIN EPIDEMIOL, HAMILTON L8S 4L8, ONTARIO, CANADA
[5] MCMASTER UNIV, DEPT BIOSTAT, HAMILTON L8S 4L8, ONTARIO, CANADA
关键词
D O I
10.1046/j.1537-2995.1985.25385219919.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:286 / 288
页数:3
相关论文
共 15 条
[1]  
ALI MAM, 1978, CAN MED ASSOC J, V118, P945
[2]  
FINCH CA, 1977, BLOOD, V50, P441
[3]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[4]   HEMOGLOBIN EVALUATION AND DONOR ACCEPTANCE - ERROR [J].
HYAMS, L .
TRANSFUSION, 1967, 7 (06) :432-&
[5]  
LUXTON AW, 1977, CLIN CHEM, V23, P683
[6]   PRIMER ON CERTAIN ELEMENTS OF MEDICAL DECISION-MAKING [J].
MCNEIL, BJ ;
KEELER, E ;
ADELSTEIN, SJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1975, 293 (05) :211-215
[7]   IRON STORES IN MALE BLOOD-DONORS EVALUATED BY SERUM FERRITIN [J].
MILMAN, N ;
SONDERGAARD, M .
TRANSFUSION, 1984, 24 (06) :464-468
[8]   IRON BALANCE IN SUPERDONORS [J].
MONSEN, ER ;
CRITCHLOW, CW ;
FINCH, CA ;
DONOHUE, DM .
TRANSFUSION, 1983, 23 (03) :221-225
[9]   RED-CELL SIZE AS MEASURED BY COULTER MODEL-S [J].
OKUNO, T .
JOURNAL OF CLINICAL PATHOLOGY, 1972, 25 (07) :599-&