SIMPLE AND RAPID METHOD FOR THE DETERMINATION OF THE DIASTEREOMERS OF DIFENACOUM IN BLOOD AND LIVER USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

被引:17
作者
KELLY, MJ
CHAMBERS, J
MACNICOLL, AD
机构
[1] Central Science Laboratory, Ministry of Agriculture, Fisheries and Food, Slough, Berkshire SL3 7HJ, London Road
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 620卷 / 01期
关键词
D O I
10.1016/0378-4347(93)80057-B
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive high-performance liquid chromatographic method for the analysis of cis and trans diastereomers of the anticoagulant rodenticide difenacoum has been described. The methodology demonstrates potential for the analysis of diastereomers of related 4-hydroxycoumarin anticoagulants. Separations were achieved by reversed-phase chromatography on a Zorbax ODS column with gradient elution using acetonitrile-water, modified with 0.1% acetic acid, as the mobile phase. Detection of the analytes was effected by fluoresence at excitation and emission wavelengths of 310 and 390 nm, respectively. Sample preparation from both plasma and liver has been simplified to reduce preparation time and manipulation. The minimum detectable concentration of each diastereomer was 5 ng/ml. Recoveries of 100% were obtained from plasma and 93% from liver tissue. This method has been used for the investigation of the pharmacokinetics of difenacoum diastereomers in rats, and for investigation of unexplained hypoprothrombinaemic events encountered clinically.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 11 条
[1]   SYNTHETIC ESTROGENS IMPLANTATION INHIBITORS AND HYPOCHOLESTEROLEMIC AGENTS .I. TETRAHYDRONAPHTHALENE SERIES [J].
BENCZE, WL ;
BARSKY, LI ;
CARNEY, RWJ ;
RENZI, AA ;
DESTEVEN.G .
JOURNAL OF MEDICINAL CHEMISTRY, 1967, 10 (02) :138-&
[2]   EVALUATION OF THE RELATIVE EFFICACY OF VARIOUS TECHNIQUES FOR DEPROTEINIZING PLASMA SAMPLES PRIOR TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS [J].
BLANCHARD, J .
JOURNAL OF CHROMATOGRAPHY, 1981, 226 (02) :455-460
[3]   DIFENACOUM POISONING AS A CAUSE OF HEMATURIA [J].
BUTCHER, GP ;
SHEARER, MJ ;
MACNICOLL, AD ;
KELLY, MJ ;
IND, PW .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1992, 11 (06) :553-554
[4]   A COMPARISON OF ISOMERS OF WARFARIN [J].
EBLE, JN ;
WEST, BD ;
LINK, KP .
BIOCHEMICAL PHARMACOLOGY, 1966, 15 (07) :1003-&
[5]   THE DEVELOPMENT OF A BLOOD-CLOTTING RESPONSE TEST FOR DISCRIMINATING BETWEEN DIFENACOUM-RESISTANT AND SUSCEPTIBLE NORWAY RATS (RATTUS-NORVEGICUS, BERK) [J].
GILL, JE ;
KERINS, GM ;
LANGTON, SD ;
MACNICOLL, AD .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY C-PHARMACOLOGY TOXICOLOGY & ENDOCRINOLOGY, 1993, 104 (01) :29-36
[6]   DETERMINATION OF COUMARIN ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL TISSUE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. FLUORESCENCE DETECTION USING POST-COLUMN TECHNIQUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :267-276
[7]   DETERMINATION OF COUMARIN ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL TISSUE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. FLUORESCENCE DETECTION USING ION-PAIR CHROMATOGRAPHY [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :277-283
[8]  
MERCER AC, COMMUNICATION
[9]   THE MULTI-RESIDUE DETERMINATION OF COUMARIN-BASED ANTICOAGULANT RODENTICIDES IN ANIMAL MATERIALS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MUNDY, DE ;
MACHIN, AF .
JOURNAL OF CHROMATOGRAPHY, 1982, 234 (02) :427-435
[10]   INTERACTION OF WARFARIN STEREOISOMERS WITH HUMAN ALBUMIN [J].
SELLERS, EM ;
KOCHWESER, J .
PHARMACOLOGICAL RESEARCH COMMUNICATIONS, 1975, 7 (04) :331-336