IDENTIFICATION OF CD71 (TRANSFERRIN RECEPTOR) EXPRESSING ERYTHROCYTES BY MULTIPARAMETER-FLOW-CYTOMETRY (MP-FCM) - CORRELATION TO THE QUANTITATION OF RETICULOCYTES AS DETERMINED BY CONVENTIONAL MICROSCOPY AND BY MP-FCM USING A RNA-STAINING DYE

被引:40
作者
SERKE, S [1 ]
HUHN, D [1 ]
机构
[1] FREE UNIV BERLIN,KLINIKUM RUDOLF VIRCHOW CHARLOTTENBURG,INNERE MED ABT,W-1000 BERLIN 19,GERMANY
关键词
D O I
10.1111/j.1365-2141.1992.tb08252.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reticulocytes express the CD71-defined antigen, the transferrin receptor. This report describes how by means of dual-colour immunofluorescence using MP-FCM (multi-parameter-flow-cytometry) CD71+ erythrocytes can be detected regularly in blood of healthy adults. Percentages of these CD71 + erythrocytes were compared to the percentages of reticulocytes as determined by conventional microscopy using brilliant cressyl blue, and to the percentages of erythrocytes with high RNA content, as detected by MP-FCM using a RNA-staining dye (thiazole-orange). Only about two-thirds of the percentages determined by the two latter methods were detected by MP-FCM using the CD71 expression for definition of reticulocytes. Studying clinical samples, however, including both specimens with very low and very high numbers of reticulocytes, almost identical percentages were determined by all the three methods described. Studying reticulocytes in vitro. a rapid decline of the expression of the transferrin receptor was observed on reticulocytes. Due to the differential expression of the transferrin receptor on reticulocytes, different subsets of reticulocytes could be identified. The dual-colour MP-FCM method described allows for the characterization and enumeration of immature erythrocytes, representing the major subset of reticulocytes as determined by conventional methods. Furthermore, it allows for subset dissection of reticulocytes.
引用
收藏
页码:432 / 439
页数:8
相关论文
共 23 条
[1]   PHENOTYPIC ANALYSIS OF A LARGE NUMBER OF NORMAL HUMAN BONE-MARROW SAMPLE BY FLOW-CYTOMETRY [J].
ANDREONI, C ;
RIGAL, D ;
BONNARD, M ;
BERNAUD, J .
BLUT, 1990, 61 (05) :271-277
[2]  
BEUTLER E, 1955, J LAB CLIN MED, V45, P40
[3]   A TIME-SAVING DEVICE FOR THE COUNTING OF RETICULOCYTES [J].
BRECHER, G ;
SCHNEIDERMAN, M .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1950, 20 (11) :1079-1083
[4]   CELL-SURFACE ANTIGENS ON HUMAN MARROW-CELLS - DISSECTION OF HEMATOPOIETIC DEVELOPMENT USING MONOCLONAL-ANTIBODIES AND MULTIPARAMETER FLOW-CYTOMETRY [J].
CIVIN, CI ;
LOKEN, MR .
INTERNATIONAL JOURNAL OF CELL CLONING, 1987, 5 (04) :267-288
[5]   CIRCULATING RETICULOCYTES IN NORMAL ADULTS AS DETERMINED BY NEW METHYLENE BLUE METHOD [J].
DEISS, A ;
KURTH, D .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1970, 53 (04) :481-&
[6]   STUDIES OF THE TRANSFERRIN RECEPTOR ON BOTH HUMAN RETICULOCYTES AND NUCLEATED HUMAN-CELLS IN CULTURE - COMPARISON OF FACTORS REGULATING RECEPTOR DENSITY [J].
FRAZIER, JL ;
CASKEY, JH ;
YOFFE, M ;
SELIGMAN, PA .
JOURNAL OF CLINICAL INVESTIGATION, 1982, 69 (04) :853-865
[7]  
Heilmeyer L., 1932, Z KLIN MED, V121, P361
[8]  
HILLMAN RS, 1991, CYTOMETRY S, V5, P105
[9]   RETICULOCYTES [J].
KOEPKE, JF ;
KOEPKE, JA .
CLINICAL AND LABORATORY HAEMATOLOGY, 1986, 8 (03) :169-179
[10]   AN AUTOMATED OPTOELECTRONIC RETICULOCYTE COUNTER [J].
KOJIMA, K ;
NIRI, M ;
SETOGUCHI, K ;
TSUDA, I ;
TATSUMI, N .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 92 (01) :57-61