HIGH-PRECISION MR VELOCITY MAPPING BY 3D-FOURIER PHASE ENCODING WITH A SMALL NUMBER OF ENCODING STEPS

被引:35
作者
BITTOUN, J
BOURROUL, E
JOLIVET, O
IDYPERETTI, I
MOUSSEAUX, E
TARDIVON, A
PERONNEAU, P
机构
[1] INST GUSTAVE ROUSSY, INSERM, U66, F-94805 VILLEJUIF, FRANCE
[2] HOP BROUSSAIS, INSERM, U256, F-75674 PARIS 14, FRANCE
关键词
MAGNETIC RESONANCE (MR); FLOW STUDIES; VELOCITY IMAGING; FOURIER INTERPOLATION;
D O I
10.1002/mrm.1910290515
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The final result of Fourier velocity mapping is a set of images, each representing the spatial distribution of spins at a given velocity. To acquire data in a short time, the number of encoding gradient steps must be as small as possible, but this can mean sacrificing velocity resolution. We used interpolation methods to obtain high velocity resolution with a small number of encoding steps involving linear interpolation from 16 encoding steps or more and zero-filling interpolation from two to eight encoding steps. Velocity measured by interpolated Fourier-flow encoding agreed well with values obtained using a calibrated phantom. A simulation of noise on the images of the phantom showed that, for a given acquisition time, increasing number of encoding steps in the Fourier flow encoding gave better precision for velocity measurement than did averaging identical signals in phase-mapping methods.
引用
收藏
页码:674 / 680
页数:7
相关论文
共 12 条
  • [1] FOURIER SPECTROSCOPY AND CAUSALITY PRINCIPLE
    BARTHOLD.E
    ERNST, RR
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1973, 11 (01) : 9 - 19
  • [2] BITTOUN J, 1989, RADIOLOGY, V173, P413
  • [3] MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE
    BRYANT, DJ
    PAYNE, JA
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 588 - 593
  • [4] POPLITEAL ARTERY HEMODYNAMICS - MR IMAGING US CORRELATION
    DOUSSET, V
    WEHRLI, FW
    LOUIE, A
    LISTERUD, J
    [J]. RADIOLOGY, 1991, 179 (02) : 437 - 441
  • [5] MAGNETIC-RESONANCE-IMAGING THE VELOCITY VECTOR COMPONENTS OF FLUID-FLOW
    FEINBERG, DA
    CROOKS, LE
    SHELDON, P
    HOENNINGER, J
    WATTS, J
    ARAKAWA, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (06) : 555 - 566
  • [6] FAST AND EXACT FLOW MEASUREMENTS WITH THE FAST FOURIER FLOW TECHNIQUE
    HENNIG, J
    MUERI, M
    BRUNNER, P
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IMAGING, 1988, 6 (04) : 369 - 372
  • [7] QUANTITATIVE FLOW MEASUREMENT WITH THE FAST FOURIER FLOW TECHNIQUE
    HENNIG, J
    MURI, M
    BRUNNER, P
    FRIEDBURG, H
    [J]. RADIOLOGY, 1988, 166 (01) : 237 - 240
  • [8] MORAN P R, 1982, Magnetic Resonance Imaging, V1, P197
  • [9] BLOOD-FLOW IMAGING BY CINE MAGNETIC-RESONANCE
    NAYLER, GL
    FIRMIN, DN
    LONGMORE, DB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 715 - 722
  • [10] PELC NJ, 1989, BOOK ABSTRACTS SOC M, P101