A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY

被引:596
作者
FUJITA, H
TSAI, DY
ITOH, T
DOI, K
MORISHITA, J
UEDA, K
OHTSUKA, A
机构
[1] GIFU NATL COLL TECHNOL,DEPT ELECT ENGN,MOTOSU,GIFU 50104,JAPAN
[2] HITACHI MED CORP,KASHIWA,CHIBA 277,JAPAN
[3] YAMAGUCHI UNIV,DEPT RADIOL,UBE,YAMAGUCHI 755,JAPAN
[4] UNIV CHICAGO,DEPT RADIOL,KURT ROSSMAN LABS RADIOL IMAGE RES,CHICAGO,IL 60637
关键词
D O I
10.1109/42.126908
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We developed a simple method for determining the presampling modulation transfer function (MTF), which includes the unsharpness of the detector and the effect of the sampling aperture, in digital radiographic (DR) systems. With this method, the presampling MTF is determined by the Fourier transform of a "finely sampled" LSF obtained with a slightly angulated slit in a single exposure. Since the effective sampling distance becomes much smaller than the original sampling distance of the DR system, the effect of aliasing on the MTF calculations can be eliminated. We applied this method to the measurement of the presampling MTF of a computed radiographic (CR) system and discussed the directional dependence, the effect of exponential extrapolation, and the effect of different sampling distances. We showed that the technique of multiple slit exposure and exponential extrapolation of the LSF tail, which has been commonly used in analog screen-film systems, can be employed in DR systems. Furthermore, we determined the glare fraction, by means of a lead-disk method, in order to estimate the component of low-frequency drop mainly due to "glare." The results showed that the value of glare fraction was 5-6.5% and slightly dependent on the sampling distance.
引用
收藏
页码:34 / 39
页数:6
相关论文
共 19 条
  • [1] THE VALIDITY OF MONTE-CARLO SIMULATION IN STUDIES OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY
    CHAN, HP
    DOI, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (02) : 109 - 129
  • [2] DOI K, 1972, PHYS MED BIOL, V17, P241, DOI 10.1088/0031-9155/17/2/010
  • [3] DOI K, 1986, ICRU41 INT COMM RAD, P20
  • [4] DOI K, 1986, ICRU41 INT COMM RAD, P1
  • [5] DOI K, 1982, HHS FDA828187 PUB
  • [6] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .6. MTFS OF II-TV DIGITAL IMAGING-SYSTEMS
    FUJITA, H
    DOI, K
    GIGER, ML
    [J]. MEDICAL PHYSICS, 1985, 12 (06) : 713 - 720
  • [7] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .5. CHARACTERISTIC CURVES OF II-TV DIGITAL-SYSTEMS
    FUJITA, H
    DOI, K
    GIGER, ML
    CHAN, HP
    [J]. MEDICAL PHYSICS, 1986, 13 (01) : 13 - 18
  • [8] BASIC IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHIC SYSTEM WITH PHOTOSTIMULABLE PHOSPHORS
    FUJITA, H
    UEDA, K
    MORISHITA, J
    FUJIKAWA, T
    OHTSUKA, A
    SAI, T
    [J]. MEDICAL PHYSICS, 1989, 16 (01) : 52 - 59
  • [9] ACCURATE MEASUREMENT OF CHARACTERISTIC CURVES OF II-TV DIGITAL-SYSTEMS BY USE OF ALUMINUM STEPWEDGE TECHNIQUE
    FUJITA, H
    DOI, K
    [J]. MEDICAL PHYSICS, 1986, 13 (06) : 922 - 924
  • [10] BASIC IMAGING PROPERTIES OF A LARGE IMAGE INTENSIFIER TV DIGITAL CHEST RADIOGRAPHIC SYSTEM
    FUJITA, H
    DOI, K
    MACMAHON, H
    KUME, Y
    GIGER, ML
    HOFFMANN, KR
    KATAFUCHI, T
    OHARA, K
    CHAN, HP
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (04) : 328 - 335