DETERMINATION OF THE RETINOID (E)-1,2,3,4-TETRAHYDRO-1,1,4,4-TETRAMETHYL-6-(1-METHYL-2-PHENYLETHENYL)NAPHTHALENE AND ITS PHENOLIC METABOLITE IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:4
作者
RISSLER, K
FRIEDRICH, G
KNEER, J
机构
[1] DR GERHARD FRIEDRICH PHARMBIODYN,AUFTRAGSFORSCH ANALYT UNIT,W-7819 DENZLINGEN,GERMANY
[2] F HOFFMANN LA ROCHE & CO LTD,DEPT CLIN RES,PHARMACOKINET,CH-4002 BASEL,SWITZERLAND
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 565卷 / 1-2期
关键词
D O I
10.1016/0378-4347(91)80398-V
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, sensitive and specific high-performance liquid chromatographic assay was developed for the determination in plasma of (E)-1,2,3,4-tetrahydro-1,1,4, 4-tetramethyl-6-(1-methyl-2-phenylethenyl)naphthalene (1) and its phenolic metabolite (E)-4-[2-(5,6,7,8-tetrahydro-5,5,8, 8-tetramethyl-2-naphthalenyl)-2-methylethenyl]-phenol (2). An extraction procedure using protein precipitation and liquid-liquid extraction was combined with a simple column-switching technique. To minimize sample consumption, the assay was adapted to a sample volume of 200-mu-l, which was sufficient for more than 90% of all determinations. The quantification limit was 100 ng/ml for 1 and 2, whereas the detection limits were 20 and 30 ng/ml, respectively. The recoveries for 1 and 2 were 91 and 94%, respectively, using ultraviolet detection at 280 nm. The assay was used to quantify both compounds in human plasma samples.
引用
收藏
页码:375 / 382
页数:8
相关论文
共 12 条
[1]   INHIBITION OF RAT MAMMARY CARCINOGENESIS BY AN AROTINOID WITHOUT A POLAR END GROUP (RO-15-0778) [J].
BOLLAG, W ;
HARTMANN, HR .
EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1987, 23 (02) :131-135
[2]  
BOLLAG W, 1983, LANCET, V1, P860
[3]  
LOELIGER P, 1980, EUR J MED CHEM, V15, P9
[4]  
PUGLISI CV, DATA FILE HOFFMANN L
[5]  
Roth W, 1984, J Pharm Biomed Anal, V2, P289, DOI 10.1016/0731-7085(84)80079-5
[6]   FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - A NEW CHROMATOGRAPH FOR PHARMACOKINETIC DRUG-MONITORING BY DIRECT INJECTION OF BODY-FLUIDS [J].
ROTH, W ;
BESCHKE, K ;
JAUCH, R ;
ZIMMER, A ;
KOSS, FW .
JOURNAL OF CHROMATOGRAPHY, 1981, 222 (01) :13-22
[7]  
SPORN MB, 1985, CIBA F SYMP, V113, P1
[8]   THERAPEUTIC EFFECT OF THE AROTINOID RO-15-0778 ON CHEMICALLY-INDUCED RAT MAMMARY-CARCINOMA [J].
TEELMANN, K ;
BOLLAG, W .
EUROPEAN JOURNAL OF CANCER & CLINICAL ONCOLOGY, 1988, 24 (07) :1205-1209
[9]  
WOO G, DATA FILE HOFFMANN L
[10]   DETERMINATION OF HIGHLY PROTEIN-BOUND DRUGS IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN SWITCHING, EXEMPLIFIED BY THE RETINOIDS [J].
WYSS, R ;
BUCHELI, F .
JOURNAL OF CHROMATOGRAPHY, 1988, 456 (01) :33-43