CUBIC - A 3-DIMENSIONAL COLORED PROJECTION OF CONSORT 30 GENERATED TRIVARIATE FLOW CYTOMETRIC DATA

被引:2
作者
GREIMERS, R
RONGY, AM
SCHAAFLAFONTAINE, N
BONIVER, J
机构
[1] Laboratory of Pathologic Anatomy, University Hospital of Liege, Liege, B4000
来源
CYTOMETRY | 1991年 / 12卷 / 06期
关键词
3-COLOR ANALYSIS; PHYCOERYTHRIN-TEXAS RED TANDEM CONJUGATE; ENERGY TRANSFER; 7-AMINO-ACTINOMYCIN-D; COMPUTER PROGRAM; DATA DISPLAY; MOUSE LEUKEMIA; HUMAN LYMPHOCYTES;
D O I
10.1002/cyto.990120614
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The CUBIC program displays three-dimensional colored dot plots of flow cytometric trivariate data collected by unmodified commercial instruments (FACScan flow cytometer, FACS 440 cell sorter). Assuming a bimodal distribution of the fluorescence intensity of the cells, the eight theoretical subpopulations involved in a three-color fluorescence histogram are clearly localized in the 3-D space by colored dots that are clustered near each corner of a cubic frame. Rotation, tilting, and zoom functions are available. Table look-up is not needed. CUBIC was illustrated by two experiments: 1) three-color immunofluorescence of antigens on human lymphocytes using monoclonal antibodies conjugated either to fluorescein (FITC), to R-phycoerythrin (PE), or to biotin revealed by a streptavidin coupled to a PE-Texas red tandem conjugate (TC); 2) two-color immunofluorescence of CD4 and CD8 antigens on thymocytes of healthy or preleukemic mice correlated to the DNA content quantified by 7-amino-actinomycin D (7-AAD). The three fluorescences were excited by a single argon-ion laser emitting at 488 nm.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 24 条
[1]  
BONIVER J, 1990, In Vivo (Attiki), V4, P41
[2]  
DEAN PN, 1990, FLOW CYTOMETRY SORTI, P415
[3]  
DEFRESNE MP, 1986, J NATL CANCER I, V77, P1079
[4]   KINETICS OF MATURE T-CELL DEVELOPMENT IN THE THYMUS [J].
EGERTON, M ;
SCOLLAY, R ;
SHORTMAN, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (07) :2579-2582
[5]   SINGLE LASER FLOW CYTOMETRIC DETECTION OF LYMPHOCYTES BINDING 3 ANTIBODIES LABELED WITH FLUORESCEIN, PHYCOERYTHRIN AND A NOVEL TANDEM FLUOROCHROME CONJUGATE [J].
FESTIN, R ;
BJORKLAND, A ;
TOTTERMAN, TH .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 126 (01) :69-78
[6]   FLUORESCENT TANDEM PHYCOBILIPROTEIN CONJUGATES - EMISSION WAVELENGTH SHIFTING BY ENERGY-TRANSFER [J].
GLAZER, AN ;
STRYER, L .
BIOPHYSICAL JOURNAL, 1983, 43 (03) :383-386
[7]   ONLINE 3-PARAMETER DATA UPTAKE, ANALYSIS, AND DISPLAY DEVICE FOR FLOW-CYTOMETRY AND OTHER APPLICATIONS [J].
KACHEL, V ;
SCHNEIDER, H .
CYTOMETRY, 1986, 7 (01) :25-40
[8]   8-PARAMETER PC-AT BASED FLOW CYTOMETRIC DATA SYSTEM [J].
KACHEL, V ;
MESSERSCHMIDT, R ;
HUMMEL, P .
CYTOMETRY, 1990, 11 (07) :805-812
[9]  
KAPLAN HS, 1952, J NATL CANCER I, V13, P185
[10]   TOWARDS A BETTER DEFINITION OF HUMAN-LEUKOCYTE SURFACE MOLECULES [J].
KNAPP, W ;
RIEBER, P ;
DORKEN, B ;
SCHMIDT, RE ;
STEIN, H ;
VANDERBORNE, AEGK .
IMMUNOLOGY TODAY, 1989, 10 (08) :253-258