A CLOSED-LOOP SYSTEM FOR MAINTAINING CONSTANT EXPERIMENTAL MUSCLE PAIN IN MAN

被引:65
作者
ZHANG, X [1 ]
ASHTONMILLER, JA [1 ]
STOHLER, CS [1 ]
机构
[1] UNIV MICHIGAN,SCH DENT,STOMATOGNATH PHYSIOL LAB,ANN ARBOR,MI 48109
关键词
D O I
10.1109/10.222327
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reliable experimental models are needed to help improve our knowledge of how the central nervous system adapts to function in the presence of muscle pain in man. We developed a microprocessor-based control system for maintaining a constant level of experimental muscle pain. Pain was induced in the relaxed right masseter of healthy young adults by using an infusion pump to inject an algesic 0.15 mL bolus of 5% hypertonic saline over 15 s. Subjects supplied feedback on their present pain intensity (PPI) via a 10 cm long electronic visual-analog scale (VAS) and a 0.07 Hz zero-order hold. The adaptive controller identified the system dynamic response and proportional-integral-derivative (PID) controller parameters from the subject's initial response to the bolus (pain rise and fall time constants and peak amplitude) as well as his/her response to a 90 s constant infusion. Finally, using the pain feedback the adaptive PID controller was successfully used to adjust the infusion rate to maintain PPI in five out of seven healthy adults at a mean (SD) 4.8(0.9) PPI level with respect to the 5.0 PPI setpoint for periods up to 15 min (when the experiment was arbitrarily terminated). The infusion rate required to maintain the given level of masseter pain was found to increase by approximately 3 to 5%/minute.
引用
收藏
页码:344 / 352
页数:9
相关论文
共 20 条
[1]   CERVICAL MUSCLE MYOELECTRIC RESPONSE TO ACUTE EXPERIMENTAL STERNOCLEIDOMASTOID PAIN [J].
ASHTONMILLER, JA ;
MCGLASHEN, KM ;
HERZENBERG, JE ;
STOHLER, CS .
SPINE, 1990, 15 (10) :1006-1012
[2]  
Christensen L V, 1967, Tandlaegebladet, V71, P1171
[3]  
CHRISTENSEN LV, 1990, TANDLAEGELADET, V74, P175
[4]  
CHRISTENSEN LV, 1980, PAIN, V8, P207
[5]  
Dubner R, 1980, PAIN, P63
[6]   MODELING THE RATE OF PREMATURE VENTRICULAR CONTRACTIONS AND ITS RESPONSE TO LIDOCAINE INFUSION [J].
JANNETT, TC ;
SHEPPARD, LC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (08) :636-641
[7]  
KELLGRENJH, 1937, CLIN SCI, V3, P175
[8]  
LANDRIANI GS, 1983, COMPUT PROG BIOMED, V16, P35, DOI 10.1016/0010-468X(83)90006-5
[9]   AN OPEN-LOOP COMPUTER-BASED DRUG INFUSION SYSTEM [J].
MARTIN, RW ;
HILL, HF ;
YEE, HC ;
SAEGER, LC ;
WALTER, MH ;
CHAPMAN, CR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1987, 34 (08) :642-649
[10]  
PHILLIPS CL, 1988, FEEDBACK CONTROL SYS