SUPERPARAMAGNETIC IRON-OXIDE HEPATIC MR-IMAGING - EFFICACY AND SAFETY USING CONVENTIONAL AND FAST SPIN-ECHO PULSE SEQUENCES

被引:37
作者
SCHWARTZ, LH
SELTZER, SE
TEMPANY, CMC
SILVERMAN, SG
PIWNICAWORMS, DR
ADAMS, DF
HERMAN, L
HERMAN, LA
HOOSHMAND, R
机构
[1] Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, 02115
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1995年 / 5卷 / 05期
关键词
LIVER; MR; CONTRAST ENHANCEMENT; PULSE SEQUENCES;
D O I
10.1002/jmri.1880050516
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the technical efficacy and safety of iv ferumoxides (Feridex(a)), a superparamagnetic iron oxide contrast agent for detection of hepatic lesions using conventional spin-echo and fast spin-echo MR images. Precontrast and postcontrast MR studies were performed on 25 patients with suspected focal hepatic lesions, Conventional T1- and T2-weighted MR images, as well as fast spin-echo and fat suppressed fast spin-echo MR images, were evaluated, Quantitative assessment of the contrast agent was performed obtaining region of interest measurements of the liver, spleen, and selected hepatic lesions. The pulse sequences were also evaluated subjectively for overall image quality and a subjective assessment of lesion detection. The use of a superparamagnetic iron oxide contrast agent led to a decrease in hepatic signal intensity on all pulse sequences. Lesion-to-liver contrast increased 41.1%, 36.5%, and 32.0% on the conventional T2, fast spin-echo, and fat suppressed fast spin echo pulse sequences, respectively, Lesion-to-liver contrast decreased on the T1-weighted postcontrast pulse sequence by 23.8%. Despite improvement in lesion-to-liver contrast, radiologists subjectively preferred the precontrast sequences because of overall better image quality. At a dose of 10 mu mol/kg, ferumoxides favorably impacts lesion-to-liver contrast, and may be useful in hepatic imaging, more with conventional Ta-weighted spin-echo pulse sequences than with T2-weighted fast spin-echo pulse sequences.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 16 条
[1]  
Weissleder R, Stark DD, Engelstad BL, Superparamagnetic iron oxide: pharmacokinetics and toxicity, AJR, 152, pp. 167-173, (1989)
[2]  
Saini S, Stark DD, Hahn PF, Et al., Ferrite particles: a super‐paramagnetic MR contrast agent for enhanced detection of liver carcinoma, Radiology, 162, pp. 217-222, (1987)
[3]  
Stark DD, Weissleder R, Ellzando G, Et al., Superparamagnetlc iron oxide: clinical application as a contrast agent for MR Imaging of the liver, Radiology, 168, pp. 297-301, (1988)
[4]  
Marchal G, van Hecke P, Demaerel P, Et al., Detection of liver metastases with Superparamagnetic iron oxide in 15 patients: results of MR Imaging at 1.5 T, AJR, 152, pp. 771-775, (1989)
[5]  
Winter TC, Freeny PC, Nghiew HV, Et al., MR Imaging with tv Superparamagnetic iron oxide: efficacy in the detection of focal hepatic lesions, AJR, 161, pp. 1191-1198, (1993)
[6]  
Low RN, Francis IR, Sigeti JS, Et al., Abdominal MRI imaging: comparison of T2‐weighted fast and conventional spin‐echo and contrast‐enhanced fast multiplanar spoiled gradient recalled Imaging, Radiology, 186, pp. 803-811, (1993)
[7]  
Schwartz LH, Seltzer SE, Tempany CMC, Et al., Prospective comparison of T2‐weighted fast spin echo, with and without fat suppression, and conventional spin echo pulse sequences in the upper abdomen, Radiology, 189, pp. 411-416, (1993)
[8]  
Catasca JV, Mirowitz SA, T2‐weighted MR imaging of the abdomen: fast spin‐echo vs conventional spin‐echo sequences, AJR, 162, pp. 61-67, (1994)
[9]  
Fretz CJ, Stark DD, Metz CE, Et al., Detection of hepatic metastases: comparison of contrast‐enhanced CT, unenhanced MR Imaging, and iron oxide‐enhanced MR imaging, AJR, 155, pp. 763-770, (1990)
[10]  
Mendonca-Diaz MH, Lauterbur PC, Ferromagnetic particles as contrast agents for magnetic resonance Imaging of liver and spleen, Magn Reson Med, 3, pp. 328-330, (1986)