APPLICATION OF COLLOIDAL GOLD FOR CHARACTERIZATION OF SUPPORTS USED IN SIZE-EXCLUSION CHROMATOGRAPHY

被引:5
作者
HOLTZHAUER, M
RUDOLPH, M
机构
[1] CENT INST MOLEC BIOL, DEPT CHEM, O-1115 BERLIN, GERMANY
[2] CENT INST CANC RES, DEPT VIROL, O-1115 BERLIN, GERMANY
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 605卷 / 02期
关键词
D O I
10.1016/0021-9673(92)85236-M
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Calibration of matrices for size-exclusion (gel permeation) chromatography (SEC) has to be done for the characterization of supports with inert pores and to allow the determination of the molecular masses of macromolecules. It has been shown by several groups that for steric reasons SEC is very sensitive to conformational details of macromolecules (e.g., rods or random coils). Therefore, no set of particles, organic macromolecules or biomacromolecules such as proteins exists which is universally applicable for calibration and characterization of chromatographic supports. It is shown that colloidal gold, which behaves in SEC as macromolecules, offers the advantage of hydrophilic particles with ideally spherical form and easily measured diameters. Therefore. collodial gold can be used for monitoring of the SEC process at the electron microscopic level, for the characterization of supports (determination of pore size) and for the determination of exclusion limits of matrices.
引用
收藏
页码:193 / 198
页数:6
相关论文
共 14 条
[1]   ACCURACY AND PRECISION IN THE DETERMINATION OF STOKES RADII AND MOLECULAR MASSES OF PROTEINS BY GEL-FILTRATION CHROMATOGRAPHY [J].
CABRE, F ;
CANELA, EI ;
CANELA, MA .
JOURNAL OF CHROMATOGRAPHY, 1989, 472 (02) :347-356
[2]   FUNDAMENTALS OF THE THEORY AND PRACTICE OF POLYMER GEL-PERMEATION CHROMATOGRAPHY AS A METHOD OF CHROMATOGRAPHIC POROSIMETRY [J].
GORBUNOV, AA ;
SOLOVYOVA, LY ;
PASECHNIK, VA .
JOURNAL OF CHROMATOGRAPHY, 1988, 448 (03) :307-332
[3]  
Hagel L., 1988, AQUEOUS SIZE EXCLUSI, P119
[4]   HIGH-PERFORMANCE SIZE-EXCLUSION LIQUID-CHROMATOGRAPHY OF INORGANIC COLLOIDS [J].
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1979, 185 (DEC) :273-288
[5]  
LASCH J, 1982, AFFINITY CHROMATOGR, P245
[6]   THE USE OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF SIZE AND MOLECULAR-WEIGHT OF PROTEINS - A CAUTION AND A LIST OF MEMBRANE-PROTEINS SUITABLE AS STANDARDS [J].
LEMAIRE, M ;
AGGERBECK, LP ;
MONTEILHET, C ;
ANDERSEN, JP ;
MOLLER, JV .
ANALYTICAL BIOCHEMISTRY, 1986, 154 (02) :525-535
[7]   THE USE OF GEL CHROMATOGRAPHY FOR THE DETERMINATION OF SIZES AND RELATIVE MOLECULAR MASSES OF PROTEINS - INTERPRETATION OF CALIBRATIONS IN TERMS OF GEL-PORE-SIZE DISTRIBUTION [J].
LEMAIRE, M ;
GHAZI, A ;
MOLLER, JV ;
AGGERBECK, LP .
BIOCHEMICAL JOURNAL, 1987, 243 (02) :399-404
[8]   SIZE EXCLUSION CHROMATOGRAPHY AND UNIVERSAL CALIBRATION OF GEL COLUMNS [J].
LEMAIRE, M ;
VIEL, A ;
MOLLER, JV .
ANALYTICAL BIOCHEMISTRY, 1989, 177 (01) :50-56
[10]   EFFECTS OF COUPLING METHOD AND LIGAND CONCENTRATION ON ADSORPTION EQUILIBRIUM IN IMMUNOAFFINITY CHROMATOGRAPHY [J].
SADA, E ;
KATOH, S ;
KONDO, A ;
KIYOKAWA, A .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1986, 19 (06) :502-506