AUGMENTATION OF MENISCAL REPAIRS WITH CYANOACRYLATE GLUE

被引:22
作者
KOUKOUBIS, TD [1 ]
GLISSON, RR [1 ]
FEAGIN, JA [1 ]
SEABER, AV [1 ]
VAIL, TP [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT SURG,DIV ORTHOPAED SURG,ORTHOPAED RES LAB,DURHAM,NC 27710
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1995年 / 29卷 / 06期
关键词
D O I
10.1002/jbm.820290607
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cyanoacrylate glues are biodegradable, bacteriostatic, hemostatic adhesives which have been used experimentally in surgical procedures on many tissues. This study evaluates the efficacy of cyanoacrylate glues used for in vitro bovine meniscus repair. Our hypothesis was that a local adhesive might improve fixation of meniscus fears reapproximated with suture, or obviate the need for suture. Three high-viscosity flexible cyanoacrylate glues were tested and their tensile strengths compared to those of suture alone and suture augmented with glue. The flexible formulation enables the glue to deform with the meniscus during movement of the knee joint. Bovine meniscus tissue was used as the model to compare the tensile strength at the meniscus repair site using the 300 cps glue in combination with 3-0 prolene suture, 300 cps cyanoacrylate glue alone, and suture alone. Twenty specimens were included in each repair group, and the peak load to failure was normalized for surface area and subjected to analysis of variance. Results of the analysis showed that the peak load to failure of the combination of cyanoacrylate glue plus suture was significantly higher than that of glue alone (P < .0001), but not significantly higher than that of suture alone (P = .18). However, in tissues repaired with suture, tissue separation at the tear site was noted almost immediately after distraction started, as a result of the elasticity of the suture. The combination of cyanoacrylate glue plus suture provided the maximum tensile strength before tissue separation. Because tissue separation may interfere with the meniscal healing process, glue used in combination with suture appears to offer some advantage mechanically. The cyanoacrylate formulations studied did not seem suitable for use without suture in meniscus repair. (C) 1995 John Wiley & sons, Inc.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 48 条
[1]   THE USE OF BUTYL CYANOACRYLATE AS A TISSUE ADHESIVE IN MAXILLO-FACIAL AND CRANIOFACIAL SURGERY [J].
AVERY, BS ;
ORD, RA .
BRITISH JOURNAL OF ORAL SURGERY, 1982, 20 (02) :84-95
[2]   TREATMENT OF INTRA-CEREBRAL ARTERIOVENOUS-MALFORMATIONS WITH ISOBUTYL 2-CYANOACRYLATE - INITIAL CLINICAL-EXPERIENCE [J].
BANK, WO ;
KERBER, CW ;
CROMWELL, LD .
RADIOLOGY, 1981, 139 (03) :609-616
[3]   MENISCAL TEARS - THE EFFECT OF MENISCECTOMY AND OF REPAIR ON INTRAARTICULAR CONTACT AREAS AND STRESS IN THE HUMAN KNEE - A PRELIMINARY-REPORT [J].
BARATZ, ME ;
FU, FH ;
MENGATO, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (04) :270-275
[4]  
Barber F A, 1987, Arthroscopy, V3, P25, DOI 10.1016/S0749-8063(87)80006-3
[5]  
BONUTTI PM, 1988, CLIN ORTHOP RELAT R, V229, P241
[6]   THE EFFECT OF MEDIAL MENISCECTOMY ON STRAIN DISTRIBUTION IN THE PROXIMAL PART OF THE TIBIA [J].
BOURNE, RB ;
FINLAY, JB ;
PAPADOPOULOS, P ;
ANDREAE, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09) :1431-1437
[7]   DURABILITY OF THE BOND BETWEEN BONE AND VARIOUS 2-CYANOACRYLATES IN AN AQUEOUS ENVIRONMENT [J].
BRAUER, GM ;
KUMPULA, JW ;
TERMINI, DJ ;
DAVIDSON, KM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (04) :593-606
[8]  
CASANOVA R, 1987, Journal of Reconstructive Microsurgery, V3, P201, DOI 10.1055/s-2007-1006986
[9]  
COX JS, 1975, CLIN ORTHOP RELAT R, V109, P178
[10]   OPEN MENISCUS REPAIR - TECHNIQUE AND 2 TO 9 YEAR RESULTS [J].
DEHAVEN, KE ;
BLACK, KP ;
GRIFFITHS, HJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1989, 17 (06) :788-795