CT-GUIDED BONE-BIOPSY PERFORMED BY MEANS OF A COAXIAL BIOPSY SYSTEM WITH AN ECCENTRIC DRILL

被引:29
作者
AHLSTROM, KH
ASTROM, KGO
机构
[1] Department of Diagnostic Radiology, Akademiska Sjukhuset, University Hospital
关键词
BONE MARROW; BIOPSY; BONE NEOPLASMS; DIAGNOSIS; BONES; INTERVENTIONAL PROCEDURES; TECHNOLOGY;
D O I
10.1148/radiology.188.2.8327713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Thirty-seven consecutive bone biopsies guided with computed tomography were performed in 32 patients by use of three different techniques to penetrate cortical bone and gain access to the lesion. The following instruments were used: a thin bone biopsy needle (12 biopsies), a conventional drill with an outer cannula (six biopsies), and a coaxial biopsy system that consists of a drill with an eccentric tip and an outer cannula (19 biopsies). This eccentric drill makes a hole in the bone larger than the diameter of the cannula and thereby makes it easy to advance the cannula over the drill until the cannula is anchored in the bone. One can then obtain multiple samples through the cannula. The thin bone biopsy needle could not penetrate thick (8 mm thick) cortical bone. The outer cannula was not anchored in the bone when the conventional drill was used. In 16 biopsies, the new coaxial biopsy system penetrated cortical bone with a thickness of 1-8 mm and was anchored there, and lesion samples were obtained through the anchored cannula.
引用
收藏
页码:549 / 552
页数:4
相关论文
共 13 条
[1]   VERTEBRAL TREPHINE BIOPSY [J].
ACKERMANN, W .
ANNALS OF SURGERY, 1956, 143 (03) :373-385
[2]  
ADAPON BD, 1981, J COMPUT ASSIST TOMO, V5, P73, DOI 10.1097/00004728-198102000-00014
[3]   PERCUTANEOUS BIOPSIES OF THE THORACIC SPINE UNDER CT GUIDANCE - TRANSCOSTOVERTEBRAL APPROACH [J].
BRUGIERES, P ;
GASTON, A ;
HERAN, F ;
VOISIN, MC ;
MARSAULT, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :446-448
[4]   PERCUTANEOUS NEEDLE-BIOPSY OF LONG-BONE LESIONS FACILITATED BY THE USE OF A HAND DRILL [J].
COHEN, MA ;
ZORNOZA, J ;
FINKELSTEIN, JB .
RADIOLOGY, 1981, 139 (03) :750-751
[5]   VERTEBRAL-BODY BIOPSY [J].
CRAIG, FS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1956, 38 (01) :93-102
[6]  
GEREMIA GK, 1992, AM J NEURORADIOL, V13, P169
[7]  
HAUENSTEIN KH, 1988, RADIOLOGE, V28, P251
[8]   PERCUTANEOUS BONE-BIOPSY WITH A SIMPLE PUNCH INSTRUMENT - INDICATIONS, RESULTS AND COMPLICATIONS [J].
JACOBSSON, H .
ACTA RADIOLOGICA-DIAGNOSIS, 1982, 23 (04) :415-422
[9]  
JAMSHIDI K, 1971, J LAB CLIN MED, V77, P335
[10]   THORACIC SPINE - PERCUTANEOUS TREPHINE BIOPSY [J].
LAREDO, JD ;
BARD, M .
RADIOLOGY, 1986, 160 (02) :485-489