DIFFUSION AND PERFUSION IN HIGH-RESOLUTION NMR IMAGING AND MICROSCOPY

被引:5
作者
AHN, CB [1 ]
CHO, ZH [1 ]
机构
[1] KOREA ADV INST SCI & TECHNOL,DEPT ELECT SCI,SEOUL,SOUTH KOREA
关键词
D O I
10.1002/mrm.1910190207
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion and perfusion phenomena under strong gradient fields (∼100 G/cm) are examined in high resolution nuclear magnetic resonance (NMR) imaging and microscopy, where diffusion‐associated signal attenuation predominates over T1 and T2 relaxation decays. Image contrast based on the diffusion and microcirculation is discussed with experimental results obtained with a 7.0‐T microscopy system. Ultimate resolution limit due to diffusion is investigated in high resolution NMR imaging and microscopy. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:228 / 232
页数:5
相关论文
共 17 条
[1]   NUCLEAR-MAGNETIC-RESONANCE IMAGING OF A SINGLE CELL [J].
AGUAYO, JB ;
BLACKBAND, SJ ;
SCHOENIGER, J ;
MATTINGLY, MA ;
HINTERMANN, M .
NATURE, 1986, 322 (6075) :190-191
[2]   A GENERALIZED FORMULATION OF DIFFUSION EFFECTS IN MU-M RESOLUTION NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
AHN, CB ;
CHO, ZH .
MEDICAL PHYSICS, 1989, 16 (01) :22-28
[3]   THE EFFECTS OF RANDOM DIRECTIONAL DISTRIBUTED FLOW IN NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1987, 14 (01) :43-48
[4]  
AHN CB, 1989, INVEST OPHTH VIS SCI, V30, P1612
[5]   AN IMPROVED NUCLEAR-MAGNETIC-RESONANCE DIFFUSION-COEFFICIENT IMAGING METHOD USING AN OPTIMIZED PULSE SEQUENCE [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1986, 13 (06) :789-793
[6]   DIFFUSION-LIMITED RESOLUTION IN NUCLEAR MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT ;
ECCLES, CD .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :1-8
[7]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[8]  
Cho Z. H., 1990, Journal of Visual Communication and Image Representation, V1, P56, DOI 10.1016/1047-3203(90)90016-O
[9]   THE EFFECTS OF RANDOM DIRECTIONAL DISTRIBUTED FLOW IN NUCLEAR-MAGNETIC-RESONANCE IMAGING - REPLY [J].
CHO, ZH ;
AHN, CB .
MEDICAL PHYSICS, 1987, 14 (06) :1092-1093
[10]   NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS [J].
CHO, ZH ;
AHN, CB ;
JUH, SC ;
LEE, HK ;
JACOBS, RE ;
LEE, S ;
YI, JH ;
JO, JM .
MEDICAL PHYSICS, 1988, 15 (06) :815-824