DIRECTIONAL LOW-PASS FILTERING FOR IMPROVED ACCURACY AND REPRODUCIBILITY OF STENOSIS QUANTIFICATION IN CORONARY ARTERIOGRAMS

被引:26
作者
SUN, Y [1 ]
LUCARIELLO, RJ [1 ]
CHIARAMIDA, SA [1 ]
机构
[1] OUR LADY MERCY MED CTR, DIV CARDIOL, BRONX, NY 10466 USA
关键词
D O I
10.1109/42.387705
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This Raper concerns the quantification of percent diameter stenosis in digital coronary arteriograms of low spatial resolution. To improve accuracy and reproducibility an edge-preserving smoothing method, called the directional low-pass filter (DLF), was developed to suppress quantum noise by averaging image intensity in a direction parallel to the vessel border. Accuracy of stenosis quantification was assessed by using stenosis phantoms. The standard error of the estimate (SEE) was 0.76 pixel-length (p) without spatial filtering and further reduced to 0.50 p by DLF; the average deviation as a measure of the regularity Of border definition was also reduced by DLF from 1.00 to 0.68 p (n = 50, P < 0.001). It was shown that the DLF outperformed the conventional moving average filter and median filter. Reproducibility in terms of intraframe variability was assessed by using coronary arteriograms obtained from 10 patients, intraframe variability of the percent stenosis measurements was reduced from 3.5% to 2.9% by DLF (n = 10, P < 0.005). An analysis of variance showed, however, that the interframe variability cannot be reduced by any of the spatial filters under investigation. The result of this study has provided a guideline for angiographically based quantification of percent stenosis under limited imaging resolution and suggests a new method for improving accuracy and reproducibility by directional low-pass filtering.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 16 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BROWN BG, 1986, PROG CARDIOVASC DIS, V28, P403
[3]  
CHRISTENSEN EE, 1978, INTRO PHYSICS DIAGNO, P137
[4]   VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS [J].
DEROUEN, TA ;
MURRAY, JA ;
OWEN, W .
CIRCULATION, 1977, 55 (02) :324-328
[5]   DYNAMIC CORONARY STENOSIS [J].
GOULD, KL .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) :286-292
[6]   ANGIOGRAPHIC CHANGES PRODUCED BY PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
HOLMES, DR ;
VLIETSTRA, RE ;
MOCK, MB ;
REEDER, GS ;
SMITH, HC ;
BOVE, AA ;
BRESNAHAN, JF ;
PIEHLER, JM ;
SCHAFF, HV ;
ORSZULAK, TA .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (05) :676-683
[7]  
JACKSON LB, 1990, SIGNAL SYSTEMS TRANS, P31
[9]   A COMPARISON OF DIGITAL ALGORITHMS USED IN COMPUTING THE DERIVATIVE OF LEFT-VENTRICULAR PRESSURE [J].
MARBLE, AE ;
MCINTYRE, CM ;
HASTINGSJAMES, R ;
HOR, CW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (07) :524-529
[10]   QUANTIFICATION OF RELATIVE CORONARY ARTERIAL-STENOSIS BY CINEVIDEODENSITOMETRIC ANALYSIS OF CORONARY ARTERIOGRAMS [J].
NICHOLS, AB ;
GABRIELI, CFO ;
FENOGLIO, JJ ;
ESSER, PD .
CIRCULATION, 1984, 69 (03) :512-522