HEMOSCAN(TM) - A DIALYSIS MACHINE-INTEGRATED BLOOD-VOLUME MONITOR

被引:59
作者
PAOLINI, F
MANCINI, E
BOSETTO, A
SANTORO, A
机构
[1] HOSP DASCO SPA, MEDOLLA, ITALY
[2] OSPED S ORSOLA MALPIGHI, DIV NEPHROL & DIALYSIS, BOLOGNA, ITALY
关键词
BLOOD VOLUME; HYPOVOLEMIA; HEMODYNAMICS; HYPOTENSION;
D O I
10.1177/039139889501800902
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe an opto-electronic device capable of measuring the hemoglobin concentration (Hgb) non-invasively and continuously, hence the percentage changes in blood volume (BV) during dialysis treatment by means of the optical absorption of monochromatic light by the blood in the arterial line. This method has been validated during several in vitro and in vivo tests, during which the system has shown a low sensitivity to all the common intra-dialytic interference factors, such as oxygen saturation (max err.=1.6%), blood flow (max. err. =1.8%), osmotic pressure (max err.=0.7%) and hydraulic pressure (max err.=O.6%), a high precision (std. err.<0.l g/dl) and a good accordance (Hgb mean err.=0.1 g/dl; std. err.=0.38 g/dl; BV mean err.=0.1%; std. err.=1.6%) with the corresponding values derived from standard laboratory tests.
引用
收藏
页码:487 / 494
页数:8
相关论文
共 14 条
[1]   LIGHT-ABSORBING AND SCATTERING PROPERTIES OF NON-HAEMOLYSED BLOOD [J].
ANDERSON, NM ;
SEKELJ, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (02) :170-&
[2]  
FLEMING SJ, 1988, CLIN NEPHROL, V29, P63
[3]   SERIAL BLOOD WATER ESTIMATIONS AND IN-LINE BLOOD VISCOMETRY - THE CONTINUOUS MEASUREMENT OF BLOOD-VOLUME DURING DIALYSIS PROCEDURES [J].
GREENWOOD, RN ;
ALDRIDGE, C ;
CATTELL, WR .
CLINICAL SCIENCE, 1984, 66 (05) :575-583
[4]   STUDY OF ABSORPTION AND SCATTERING FACTORS OF LIGHT IN WHOLE-BLOOD [J].
JANSSEN, FJ .
MEDICAL & BIOLOGICAL ENGINEERING, 1972, 10 (02) :231-+
[5]  
KIRSCHBAUM B, 1989, INT J ARTIF ORGANS, V12, P307
[6]   NEWLY DEVELOPED CIRCULATING BLOOD VOLUME-MONITORING SYSTEM AND ITS CLINICAL-APPLICATION FOR MEASURING CHANGES IN BLOOD-VOLUME DURING HEMOFILTRATION [J].
MAEDA, K ;
SHINZATO, T ;
YOSHIDA, F ;
TSURUTA, Y ;
USUDA, M ;
YAMADA, K ;
ISHIHARA, T ;
INAGAKI, F ;
IGARASHI, I ;
KITANO, T .
ARTIFICIAL ORGANS, 1986, 10 (06) :452-459
[7]  
MANCINI E, 1993, ARTIF ORGANS, V17, P691
[8]  
MANCINI E, 1992, ROLE HYPOVOLEMIA DIA, V2, P68
[9]   WAVELENGTH DEPENDENCY OF SPECTROPHOTOMETRIC DETERMINATION OF BLOOD OXYGEN SATURATION [J].
MOOK, GA ;
VANASSEN.OW ;
ZIJLSTRA, WG .
CLINICA CHIMICA ACTA, 1969, 26 (01) :170-&
[10]  
SCHALLENBERG U, 1987, LIFE SUPPORT SYST, V5, P293