NO EVIDENCE FOR ISOTOPE DISCRIMINATION OF TRITIATED GLUCOSE TRACERS IN MEASUREMENTS OF GLUCOSE-TURNOVER RATES IN MAN

被引:28
作者
KOIVISTO, VA [1 ]
YKIJARVINEN, H [1 ]
PUHAKAINEN, I [1 ]
VIRKAMAKI, A [1 ]
KOLACZYNSKI, J [1 ]
DEFRONZO, R [1 ]
机构
[1] UNIV TEXAS SAN ANTONIO, SAN ANTONIO, TX 78285 USA
关键词
Glucose metabolism; hyperinsulinaemia; radioisotope effect; tritiated glucose;
D O I
10.1007/BF00404045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Under non-steady-state conditions, glucose turnover rates determined with tritiated glucose tracers are often underestimated. To examine whether isotope discrimination or a tracer contaminant can contribute to this, we compared the turnover rates of unlabelled and tritiated glucose under isotopic steady-state conditions. The turnover rates were measured in 20 healthy subjects at two insulin concentrations (79±3 mU·l-1 and 704±62 mU·l-1). Euglycaemia was maintained by infusing unlabelled glucose mixed with (33H)-or (63H)-glucose. In both studies, the isotopically determined glucose disposal rate was virtually identical to the exogenous glucose infusion rate (low insulin 7.66±0.48 vs 7.58±0.44 mg·kg-1·min-1, high insulin 13.36±0.74 vs 13.55±0.98 mg·kg-1·min-1). The individual values were correlated in both the low (r = 0.85, p<0.001) and high dose insulin (r=0.81, p<0.001) studies. Tritiated glucose specific activities were also compared in arterialized and deep venous blood across forearm tissues during the high-dose insulin infusion. Glucose specific activities were similar in arterilized and deep venous blood when analysed with HPLC and conventional methods. In summary: (1) Under isotopic steady-state conditions the turnover rates of unlabelled and labelled glucoses are similar. (2) Unlabelled and labelled glucose are handled identically across forearm tissues. (3) We found no tracer impurity in our tritiated glucose preparations. We conclude that (33H)- and (63H)-glucose tracers can be used to reliably measure glucose turnover rates in man. © 1990 Springer-Verlag.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 22 条
[1]   GLUCOSE TURNOVER VALUES IN DOG OBTAINED WITH VARIOUS SPECIES OF LABELED GLUCOSE [J].
ALTSZULER, N ;
BARKAI, A ;
BJERKNES, C ;
GOTTLIEB, B ;
STEELE, R .
AMERICAN JOURNAL OF PHYSIOLOGY, 1975, 229 (06) :1662-1667
[2]   UNDERESTIMATION OF HEPATIC GLUCOSE-PRODUCTION BY RADIOACTIVE AND STABLE TRACERS [J].
ARGOUD, GM ;
SCHADE, DS ;
EATON, RP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (05) :E606-E615
[3]   THE EFFECTS OF HYPERGLYCEMIA ON ISOTOPIC MEASUREMENT OF GLUCOSE-UTILIZATION USING [2H-3], [3H-3] AND [6C-14] GLUCOSE IN PATIENTS WITH TYPE-1 (INSULIN-DEPENDENT) DIABETES-MELLITUS [J].
BELL, PM ;
FIRTH, RG ;
RIZZA, RA .
DIABETOLOGIA, 1987, 30 (06) :365-371
[4]   ASSESSMENT OF INSULIN ACTION IN INSULIN-DEPENDENT DIABETES-MELLITUS USING [6C-14] GLUCOSE, [3H-3] GLUCOSE, AND [2H-3] GLUCOSE - DIFFERENCES IN THE APPARENT PATTERN OF INSULIN RESISTANCE DEPENDING ON THE ISOTOPE USED [J].
BELL, PM ;
FIRTH, RG ;
RIZZA, RA .
JOURNAL OF CLINICAL INVESTIGATION, 1986, 78 (06) :1479-1486
[5]   ASSESSMENT OF INSULIN SENSITIVITY INVIVO [J].
BERGMAN, RN ;
FINEGOOD, DT ;
ADER, M .
ENDOCRINE REVIEWS, 1985, 6 (01) :45-86
[6]   NONSTEADY STATE - ERROR ANALYSIS OF STEELES MODEL AND DEVELOPMENTS FOR GLUCOSE KINETICS [J].
COBELLI, C ;
MARI, A ;
FERRANNINI, E .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (05) :E679-E689
[7]  
DEFRONZO RA, 1979, AM J PHYSIOL, V237, pE214
[8]   EFFECT OF INSULIN ON THE DISTRIBUTION AND DISPOSITION OF GLUCOSE IN MAN [J].
FERRANNINI, E ;
SMITH, JD ;
COBELLI, C ;
TOFFOLO, G ;
PILO, A ;
DEFRONZO, RA .
JOURNAL OF CLINICAL INVESTIGATION, 1985, 76 (01) :357-364
[9]  
FERRANNINI E, 1985, METHODS DIABETES RES, V2, P19
[10]   MODELING ERROR AND APPARENT ISOTOPE DISCRIMINATION CONFOUND ESTIMATION OF ENDOGENOUS GLUCOSE-PRODUCTION DURING EUGLYCEMIC GLUCOSE CLAMPS [J].
FINEGOOD, DT ;
BERGMAN, RN ;
VRANIC, M .
DIABETES, 1988, 37 (08) :1025-1034