ACCURACY OF COLOR DOPPLER ULTRASOUND VELOCITY-MEASUREMENTS IN SMALL VESSELS

被引:14
作者
DEANE, CR
FORSBERG, F
THOMAS, N
ROBERTS, VC
机构
[1] Department of Medical Physics and Medical Engineering, King's College School of Medicine and Dentistry, Dulwich Hospital, London, SE22 8PT, East Dulwich Grove
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1991年 / 13卷 / 03期
基金
英国医学研究理事会;
关键词
COLOR DOPPLER ULTRASOUND; HYDROPHONE MEASUREMENTS; FLOW-RIG TESTS; ACUSON-128;
D O I
10.1016/0141-5425(91)90136-U
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Colour Doppler ultrasound offers the possibility of imaging small vessels not visible by B-mode alone. The colour Doppler image of velocities allows the course of small vessels to be imaged in the X-Y plane of the scan provided the Doppler frequency shift is of sufficient magnitude. This permits alignments of the Doppler cursor, allowing angle correction to provide true velocity measurements from the Doppler shift obtained. Before attempting to make velocity measurements, however, it is essential to be aware of the possible error in the Z plane caused by the thickness of the Doppler sample volume. To quantify this source of error, hydrophone and flow-rig measurements were performed on an Acuson 128 colour Doppler scanner with both 5 MHz linear-array and 3.5 MHz phased-array transducers. Measurements of the transmitted pulses using a point hydrophone showed that both probes employ approximately 3.5 MHz Doppler pulses (in both colour and pulsed Doppler modes). The two transducers have the same axial resolution. In colour Doppler mode the axial length of the sample volume increases automatically with depth by up to 0.5 mm. Measurements of colour and pulsed Doppler signal strength were obtained in a controlled flow rig. Both transducers produced accurate colour flow images of the phantom at their optimum depths; flow velocity errors due to Z-plane thickness are < 5%. There was, however, substantial error outside these optimum conditions (up to 20%).
引用
收藏
页码:249 / 254
页数:6
相关论文
共 11 条
  • [1] THE PHYSICAL PRINCIPLES OF DOPPLER AND SPECTRAL-ANALYSIS
    BURNS, PN
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1987, 15 (09) : 567 - 590
  • [2] HALBERG LI, 1986, HEWLETT-PACKARD J, V37, P35
  • [3] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE
    KASAI, C
    NAMEKAWA, K
    KOYANO, A
    OMOTO, R
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03): : 458 - 464
  • [4] KRISTOFFERSEN K, 1986, IEEE T ULTRASON FERR, V31, P51
  • [5] A SIMPLE TISSUE-LIKE ULTRASOUND PHANTOM MATERIAL
    LERSKI, RA
    DUGGAN, TC
    CHRISTIE, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (650) : 156 - 157
  • [6] DOPPLER COLOR FLOW IMAGING
    MERRITT, CRB
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1987, 15 (09) : 591 - &
  • [7] THE USE OF A DIASONICS DRF400 DUPLEX ULTRASOUND SCANNER TO MEASURE VOLUME FLOW IN ARTERIOVENOUS-FISTULAS IN PATIENTS UNDERGOING HEMODIALYSIS - AN ANALYSIS OF MEASUREMENT UNCERTAINTIES
    OATES, CP
    WILLIAMS, ED
    MCHUGH, MI
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) : 571 - 579
  • [8] Peronneau P., 1974, CARDIOVASCULAR APPL, P66
  • [9] Wells P.N.T., 1977, BIOMEDICAL ULTRASONI
  • [10] 1989, ACUSON 128 COMPUTED