TRANSCATHETER PATENT DUCTUS-ARTERIOSUS OCCLUSION - APPLICATION IN THE SMALL CHILD

被引:44
作者
NYKANEN, DG
HAYES, AM
BENSON, LN
FREEDOM, RM
机构
[1] HOSP SICK CHILDREN,DEPT PEDIAT,DIV CARDIOL,TORONTO M5G 1X8,ON,CANADA
[2] UNIV TORONTO,FAC MED,DEPT PEDIAT,TORONTO,ON,CANADA
[3] HOSP SICK CHILDREN,VARIETY CLUB CARDIAC CATHETERIZAT LABS,TORONTO,ON,CANADA
关键词
D O I
10.1016/0735-1097(94)90672-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study intended to evaluate application of transcatheter occlusion of the patent ductus arteriosus in children <10 kg body weight. Background. Transcatheter occlusion of the patent ductus arteriosus in the child weighing >10 kg has been proved safe and effective. Methods. We reviewed 74 consecutive patients weighing <10 kg (median 8.1 kg, range 3.98 to 10) and aged 4 to 30 months (median 13 months) who underwent patent ductus arteriosus occlusion between June 1986 and November 1992. A modification of the delivery system to facilitate application in small children is described. Results. A 12-mm device was implanted in 50 patients and a 17-mm device in 24. Three device embolizations occurred early in the experience, and one required removal because of hemolysis associated with a moderate residual shunt. One 17-mm device was removed at catheterization because of acute compromise to left pulmonary artery Bow after implantation. Prevalence of residual shunting was 33% at 6 months, 20% at 12 to 18 months and 17% at 2-year follow up and was not related to device, age, weight or size of the patent ductus. Altered flow to the left pulmonary artery was noted in seven patients (9.9%), with more significant com promise associated with the 17-mm device. Conclusions. Transcatheter patent ductus arteriosus occlusion is feasible in the small child <10 kg, particularly with the use of a modified delivery system. However, implantation of a 17-mm device in this patient population may impair Bow to the left lung and should be reserved for the symptomatic child.
引用
收藏
页码:1666 / 1670
页数:5
相关论文
共 17 条
[1]   CATHETER OCCLUSION OF THE PERSISTENTLY PATENT DUCTUS-ARTERIOSUS [J].
DYCK, JD ;
BENSON, LN ;
SMALLHORN, JF ;
MCLAUGHLIN, PR ;
FREEDOM, RM ;
ROWE, RD .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (16) :1089-1092
[2]  
FADLEY F, 1993, LANCET, V341, P560
[3]  
HAYES AM, 1992, BRIT HEART J, V67, P321
[4]   TRANSCATHETER OCCLUSION OF THE PERSISTENTLY PATENT DUCTUS-ARTERIOSUS - 40-MONTH FOLLOW-UP AND PREVALENCE OF RESIDUAL SHUNTING [J].
HOSKING, MCK ;
BENSON, LN ;
MUSEWE, N ;
DYCK, JD ;
FREEDOM, RM .
CIRCULATION, 1991, 84 (06) :2313-2317
[5]  
HOSKING MCK, 1989, CAN J CARDIOL, V5, P340
[6]  
HOUDE C, 1993, BRIT HEART J, V69, P56
[7]   EXPERIENCE WITH 205 PROCEDURES OF TRANSCATHETER CLOSURE OF DUCTUS-ARTERIOSUS IN 182 PATIENTS, WITH SPECIAL REFERENCE TO RESIDUAL SHUNTS AND LONG-TERM FOLLOW-UP [J].
KHAN, MAA ;
YOUSEF, SA ;
MULLINS, CE ;
SAWYER, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (06) :1721-1727
[8]   TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PEDIATRIC-PATIENTS [J].
LATSON, LA ;
HOFSCHIRE, PJ ;
KUGLER, JD ;
CHEATHAM, JP ;
GUMBINER, CH ;
DANFORD, DA .
JOURNAL OF PEDIATRICS, 1989, 115 (04) :549-553
[9]   TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PIGLETS [J].
LOCK, JE ;
BASS, JL ;
LUND, G ;
RYSAVY, JA ;
LUCAS, RV .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (06) :826-829
[10]  
MOMMA K, 1986, BRIT HEART J, V55, P39