DOSE-RATE, DOSE-EQUIVALENT RATE, AND QUALITY FACTOR IN SLS-1

被引:8
作者
BADHWAR, GD
BRABY, LA
CUCINOTTA, FA
ATWELL, W
机构
[1] NASA, LANGLEY RES CTR, HAMPTON, VA 23665 USA
[2] ROCKWELL INT INC, HOUSTON, TX 77058 USA
[3] PACIFIC NW LAB, RICHLAND, WA 99352 USA
来源
NUCLEAR TRACKS AND RADIATION MEASUREMENTS | 1992年 / 20卷 / 03期
关键词
D O I
10.1016/1359-0189(92)90030-Y
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A tissue-equivalent proportional counter (TEPC) sensitive to the lineal energy range of 0.26-300 keV-mu-m-1 was flown on STS-40 (39-degrees x 278 km x 296 km) inside the Spacelab. This instrument was previously flown on STS-31 but was modified to provide a finer resolution at lower lineal energies to better map the South Atlantic Anomaly (SAA) protons. The instrument was turned on 6 June 1991, and operated for 7470 min (124.5 h). The flight duration was characterized by a very large number of X-ray solar flares and enhanced magnetic field fluctuations; however, no significant dose from the solar particles was measured at the location of this instrument. The flight data can be separated into trapped and galactic cosmic radiation parts. The dose rate, dose-equivalent rate and quality factor for trapped radiation were 4.21 +/- 0.03 mrad day-1, 7.72 +/- 0.05 mrem day-1, and 1.83 +/- 0.1, respectively. The dose rate, dose-equivalent rate, and quality factor for galactic cosmic radiation were 5.34 +/- 0.03 mrad day-1, 14.63 +/- 0.06 mrem day-1, and 2.74 +/- 0.1, respectively. The overall quality factor for the flight was 2.38. The dose from the GCR is higher than from SAA protons because of the high inclination and low altitude of this flight. The AP8MAX model of the trapped radiation gives a dose rate of 2.43 mrad day-1 and a quality factor of 1.77. The CREME solar maximum model of galactic cosmic radiation gives a dose mte of 2.54 mrad day-1 and a quality factor of 2.91. Thus the AP8MAX model underestimates the dose by a factor of 1.8 whereas the CREME model leads to an underestimation of the dose by a factor of 2. A comparison of the LET spectra using the AP8MAX model and galactic cosmic radiation transport codes shows only a qualitative agreement.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 7 条
[1]  
ADAMS JH, 1986, NRL4506 MEM REP
[2]   ACTIVE DOSIMETRIC MEASUREMENTS ON SHUTTLE FLIGHTS [J].
BADHWAR, GD ;
KONRADI, A ;
HARDY, A ;
BRABY, LA .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (01) :13-20
[3]  
BADHWAR GD, 1991, WORKSHOP NATIONAL CO
[4]  
BADHWAR GD, 1991, 22ND INT COSM RAY C
[5]   CHORD LENGTH DISTRIBUTIONS FOR CIRCULAR-CYLINDERS [J].
MADER, U .
RADIATION RESEARCH, 1980, 82 (03) :454-466
[6]  
WILSON JW, 1991, NASA RP1257
[7]  
1977, ICRP26 INT COMM RAD