DEFIBRILLATION ENERGY-REQUIREMENTS WITH SINGLE ENDOCARDIAL (ENDOTAK(TM)) LEAD

被引:30
作者
WINTER, J [1 ]
VESTER, EG [1 ]
KUHLS, S [1 ]
KANTARTZIS, M [1 ]
PERINGS, C [1 ]
PAUSCHINGER, M [1 ]
STRAUER, BE [1 ]
BIRCKS, W [1 ]
机构
[1] UNIV DUSSELDORF,DEPT CARDIOL,W-4000 DUSSELDORF 1,GERMANY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 03期
关键词
D O I
10.1111/j.1540-8159.1993.tb01622.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The need for thoracotomy in usually high risk patients has limited the use of the implantable cardioverter defibrillator. Initial clinical results with endocardial and subcutanous patch electrodes (SQPs) are encouraging. Using a single endocardial lead in the absence of a SQP for chronic implantation of the cardioverter defibrillator, the goal of the study was to obtain defibrillation thresholds (DFTs) of 15 Joules (j) or less and to investigate changes in DFT over time. We tested 19 consecutive patients (15 men, 4 women) age 62 +/- 8.5 years with malignant ventricular arrhythmias (14 VT/5 VF). The underlying heart disease was coronary artery disease in 15 patients, dilative cardiomyopathy in two patients, and primary electrical disease in two patients. Four patients had undergone previous cardiac surgery. Left ventricular ejection fraction ranged between 14% and 66% (39% +/- 12.6%). Pacing thresholds (0.54 +/- 0.17 V at 0.5 msec), R wave amplitude for pacemaker sensing (14.2 +/- 7.0 mV), slew rate (2.12 +/- 1.4 V/sec), and resistance (500.3 +/- 73.9 W) were sufficient in all patients. Eighteen patients met our endocardial implant criteria with a DFT less-than-or-equal-to 15 J (10.05 +/- 4.03 J) using monophasic (14 patients) or biphasic (four patients) pulse wave forms. In the one remaining patient, with a DFT of 20 J, we implanted a SQP but there was no reduction of the DFT. All patients tested showed successful defibrillation prior to discharge. During follow-up of 88 patient-months (1-9 months), 114 spontaneous VT/VF episodes occurred in five patients and were all successfully terminated. Eleven patients with a minimum follow-up of 2 months were reassessed. In seven out of 11 patients, termination of VF was achieved with the same minimal energy requirements obtained intraoperatively. In three patients, DFT increased by 5 J (one patient) and 10 J (two patients). In a further patient, X ray revealed dislocation of the endocardial lead. Our data suggest that effective defibrillation is feasible with a single endocardial lead for implantation of cardioverter defibrillator. In addition, we strongly recommend repetitive x-ray control to detect asymptomatic lead dislocation. Despite stable DFTs in most of our patients, an energy difference of less-than-or-equal-to 15 J between acute DFT and cardioverter defibrillator energy rating seems to be currently desirable to ensure successful postoperative defibrillation.
引用
收藏
页码:540 / 546
页数:7
相关论文
共 14 条
  • [1] TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS
    BARDY, GH
    ALLEN, MD
    MEHRA, R
    JOHNSON, G
    FELDMAN, S
    GREENE, HL
    IVEY, TD
    [J]. CIRCULATION, 1990, 81 (04) : 1252 - 1259
  • [2] INTERNAL CARDIAC DEFIBRILLATION - HISTOPATHOLOGY AND TEMPORAL STABILITY OF DEFIBRILLATION ENERGY-REQUIREMENTS
    FAIN, ES
    BILLINGHAM, M
    WINKLE, RA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (03) : 631 - 638
  • [3] HOPPS JA, 1954, SURGERY, V36, P833
  • [4] CATHETER ELECTRODE DEFIBRILLATION IN DOGS - THRESHOLD DEPENDENCE ON IMPLANT TIME AND CATHETER STABILITY
    KALLOK, MJ
    WIBEL, FH
    BOURLAND, JD
    TACKER, WA
    SCHOLLMEYER, MP
    VANVLEET, JF
    [J]. AMERICAN HEART JOURNAL, 1985, 109 (04) : 821 - 826
  • [5] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION WITHOUT THORACOTOMY USING AN ENDOCARDIAL AND SUBMUSCULAR PATCH SYSTEM
    MCCOWAN, R
    MALONEY, J
    WILKOFF, B
    SIMMONS, T
    KHOURY, D
    MCALISTER, H
    MORANT, V
    CASTLE, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) : 415 - 421
  • [6] STANDBY AUTOMATIC DEFIBRILLATOR - AN APPROACH TO PREVENTION OF SUDDEN CORONARY DEATH
    MIROWSKI, M
    MOWER, MM
    STAEWEN, WS
    TABATZNIK, B
    MENDELOFF, AI
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1970, 126 (01) : 158 - +
  • [7] FEASIBILITY AND EFFECTIVENESS OF LOW-ENERGY CATHETER DEFIBRILLATION IN MAN
    MIROWSKI, M
    MOWER, MM
    GOTT, VL
    BRAWLEY, RK
    [J]. CIRCULATION, 1973, 47 (01) : 79 - 85
  • [8] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTED BY NONTHORACOTOMY APPROACH - INITIAL CLINICAL-EXPERIENCE WITH THE REDESIGNED TRANSVENOUS LEAD SYSTEM
    MOORE, SL
    MALONEY, JD
    EDEL, TB
    MCGUINN, WP
    GOHN, D
    MORANT, VA
    TROHMAN, R
    SIMMONS, TW
    WILKOFF, BL
    CASTLE, LW
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1865 - 1869
  • [9] IMPLANTATION OF A CARDIOVERTER DEFIBRILLATOR WITHOUT THORACOTOMY USING A TRIPLE ELECTRODE SYSTEM
    SAKSENA, S
    PARSONNET, V
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (01): : 69 - 72
  • [10] INITIAL CLINICAL-EXPERIENCE WITH ENDOCARDIAL DEFIBRILLATION USING AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR WITH A TRIPLE-ELECTRODE SYSTEM
    SAKSENA, S
    TULLO, NG
    KROL, RB
    MAURO, AM
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (10) : 2333 - 2339