MR-IMAGING OF SILICONE GEL - FILLED BREAST IMPLANTS IN-VIVO WITH A METHOD THAT VISUALIZES SILICONE SELECTIVELY

被引:12
作者
MUKUNDAN, S
DIXON, WT
KRUSE, BD
MONTICCIOLO, DL
NELSON, RC
机构
[1] EMORY UNIV,SCH MED,FREDERIK PHILIPS MAGNET RESONANCE RES CTR,ATLANTA,GA 30322
[2] EMORY UNIV,SCH MED,DEPT RADIOL,DIV BREAST IMAGING,1365 CLIFTON RD NE,ATLANTA,GA 30322
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 05期
关键词
BREAST; MR; PROSTHESES; PULSE SEQUENCES; SILICONE; TISSUE SUPPRESSION;
D O I
10.1002/jmri.1880030505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The lack of an adequately sensitive method for detecting silicone leakage and reported serious complications due to silicone leakage were cited as justification by the U.S. Food and Drug Administration for imposing the current restrictions on silicone gel-filled breast prostheses. The authors report a new magnetic resonance imaging method for visualizing silicone leakage: the silicone-only sequence (SOS). The method uses the conventional STIR (short-inversion-time inversion-recovery) technique combined with a 1331 radio-frequency pulse train widely used for water suppression in spectroscopy. With the SOS, silicone can be imaged while signals from fat and water are suppressed. The authors used the SOS to image phantoms and normal and ruptured silicone gel-filled breast prostheses.
引用
收藏
页码:713 / 717
页数:5
相关论文
共 15 条
  • [1] Kessler DA, Important information on breast implants, FDA Backgrounder, 91, (1991)
  • [2] Woods JE, Arnold PG, Fiction obscures the facts of breast implants, Wall Street Journal, 16, (1992)
  • [3] Berkel H, Birdsell DC, Jenkins H, Breast augmentation: a risk factor for breast cancer?, N Engl J Med, 326, pp. 1649-1653, (1992)
  • [4] Scheman CR, Update on silicone gel‐filled breast implants, pp. 1-8, (1992)
  • [5] Kessler DA, Special report: the basis of the FDA's decision on breast implants, N Engl J Med, 326, pp. 1713-1715, (1992)
  • [6] Bydder GM, Young IR, MR imaging: clinical use of the inversion recovery sequence, J Comput Assist Tomogr, 9, pp. 659-675, (1985)
  • [7] Hore PJ, Solvent suppression in Fourier transform nuclear magnetic resonance, J Magn Reson, 55, pp. 283-300, (1983)
  • [8] Hennig J, Nauerth A, Friedburg H, RARE‐imaging: a fast method for clinical MR, Magn Reson Med, 3, pp. 823-833, (1986)
  • [9] Middleton MS, Mattrey R, Udkoff R, Dobke JR, Hesselink JR, MR imaging of silicone gel‐filled breast implants using conventional and silicone suppression techniques (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine 1992, (1992)
  • [10] Li H, Wei H, Button TM, Springer CS, Application of MRI in the visualization of breast prostheses: bulk magnetic susceptibility of silicone gel (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine 1992, (1992)