STUDY OF THE PACKING BEHAVIOR OF AXIAL-COMPRESSION COLUMNS FOR PREPARATIVE CHROMATOGRAPHY

被引:22
作者
SARKER, M
GUIOCHON, G
机构
[1] UNIV TENNESSEE,DEPT CHEM,KNOXVILLE,TN 37996
[2] OAK RIDGE NATL LAB,DIV ANALYT CHEM,OAK RIDGE,TN 37831
基金
美国国家科学基金会;
关键词
D O I
10.1016/0021-9673(95)00130-F
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The behavior of the packing of axial compression columns (5 cm I.D.) has been studied using IMPAQ C-18 silica (average particle size 17 mu m) as the stationary phase and water-methanol solutions as the eluent. Provided the frits used at both column ends are properly cleaned, columns of the same efficiency as analytical columns are easily and reproducibly obtained. The efficiencies of several columns for acetone (poorly retained), phenol (moderately retained) and cresol (strongly retained) were found to remain unchanged over periods' of 100 to 200 h. The column length was monitored during operations. It was found to decrease slowly over time, and to change when the packing solvent is replaced by the experimental eluent, and during gradient elution. It is smaller when the eluent contains more water. The total porosity and-the permeability of the axial compression columns were lower than those of analytical columns.
引用
收藏
页码:27 / 44
页数:18
相关论文
共 32 条
[1]   ADVANCED SORBENTS FOR PREPARATIVE PROTEIN SEPARATION PURPOSES [J].
BOSCHETTI, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 658 (02) :207-236
[2]  
COLIN H, 1990, LC GC-MAG SEP SCI, V8, P302
[3]   ROLE OF THE TEMPERATURE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PYROCARBON-CONTAINING ADSORBENTS [J].
COLIN, H ;
DIEZMASA, JC ;
GUIOCHON, G ;
CZAJKOWSKA, T ;
MIEDZIAK, I .
JOURNAL OF CHROMATOGRAPHY, 1978, 167 (DEC) :41-65
[4]  
DINGENEN J, 1992, PREPR 92, P359
[5]  
DOSE E, 1990, ANAL CHEM, V61, P1723
[6]   COMPARISON OF MAXIMUM PRODUCTION-RATES AND OPTIMUM OPERATING DESIGN PARAMETERS IN OVERLOADED ELUTION AND DISPLACEMENT CHROMATOGRAPHY [J].
FELINGER, A ;
GUIOCHON, G .
BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (01) :134-147
[7]  
FRANCOTTE E, 1992, J CHROMATOGR, V576, P576
[8]  
GANETSOS G, 1939, PREPARATIVE PRODUCTI
[9]   USE OF AN 18-MM ID COLUMN FOR ANALYTICAL-SCALE AND SEMI-PREPARATIVE-SCALE HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
GODBILLE, E ;
DEVAUX, P .
JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7) :317-329
[10]   OPTIMIZATION OF THE EXPERIMENTAL CONDITIONS IN PREPARATIVE LIQUID-CHROMATOGRAPHY WITH TOUCHING BANDS [J].
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1990, 517 :229-256