Reamed surface topography and component seating in press-fit cementless acetabular fixation

被引:31
作者
Kim, YS [1 ]
Brown, TD [1 ]
Pedersen, DR [1 ]
Callaghan, JJ [1 ]
机构
[1] UNIV IOWA,DEPT ORTHOPAED SURG,BIOMECH LAB,IOWA CITY,IA 52242
关键词
acetabulum; reaming; sphericity dual-radius; contact; gap;
D O I
10.1016/S0883-5403(05)80226-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Thirty-eight paired, size-matched, fresh-frozen cadaver acetabulae were used to study reamed surface topography and the seating of on-line versus oversized noncemented components. Four commonly used constructs were considered: online reamed and 2-mm oversized hemispherical cups. and on-line reamed and 1-mm oversized dual-radius cups. Reamed surface topography was indexed by three-dimensional surfaces mathematically fitted to digitized castings. Component seating was indexed by the distribution of bone-cup contact and the thickness of the gap between the component backing and the hone. The reamed surfaces were better approximated by slightly blunt ellipsoids than by spheres, especially for the smaller acetabulae. Seating of the on-line hemispherical cups was best near the pole and poorest near the equator, whereas the converse was true for the 1-mm oversized dual-radius cups. The on-line dual-radius cups offered better overall compromise between polar and equatorial contact than did the 2-mm oversized hemispherical components.
引用
收藏
页码:S14 / S21
页数:8
相关论文
共 25 条
[1]  
Russotti, Coventry, Stauffer, Cemented total hip arthroplasty with contemporary techniques a five-year minimum follow-up study, Clin Orthop Relat Res, 235, (1988)
[2]  
Maloney, Jasty, Burke, Et al., Biomechanical and histologic investigation of cemented total hip arthroplasties a study of autopsy-retrieved femurs after in vivo cycling, Clin Orthop Relat Res, 249, (1989)
[3]  
Paul, Bargar, Histologic changes in the dog acetabulum following total hip replacement with current cementing techniques, J Arthroplasty, 2, (1987)
[4]  
McCoy, Salvati, Ranawat, Wilson, A fifteen-year follow-up study of one hundred Charnley low-friction arthroplasties, Orthop Clin North Am, 19, (1988)
[5]  
Welch, McGann, Picetti, Charnley low-friction arthroplasty a fifteen- to seventeen-year follow-up study, Orthop Clin North Am, 19, (1988)
[6]  
Wroblewski, 15–21-year results of the Charnley low-friction arthroplasty, Clin Orthop, 211, (1986)
[7]  
Lachiewicz, Suh, Gilbert, In vitro initial fixation of porous-coated acetabular hip components: a biomechanical comparative study, J Arthroplasty, 4, (1989)
[8]  
Stiehl, MacMillan, Skrade, Mechanical stability of porous-coated acetabular components in total hip arthroplasty, J Arthroplasty, 6, (1991)
[9]  
Takedani, Whiteside, White, Otani, The effect of screws and pegs on cementless acetabular fixation, Trans Orthop Res Soc, 16, (1991)
[10]  
Keating, Ritter, Faris, Structures at risk from medially placed acetabular screws, J Bone Joint Surg, 72 A, (1990)