DETERMINATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH USE OF BIPHASIC SPIN-ECHO MR IMAGING - COMPARISON WITH CINE MR

被引:47
作者
CAPUTO, GR [1 ]
SUZUKI, JI [1 ]
KONDO, C [1 ]
CHO, H [1 ]
QUAIFE, RA [1 ]
HIGGINS, CB [1 ]
PARKER, DL [1 ]
机构
[1] UNIV UTAH,LATTER DAY ST HOSP,DEPT MED INFORMAT,SALT LAKE CITY,UT 84143
关键词
Heart; ejection fraction; function; MR studies; 524.1214; ventricles; volume; Magnetic resonance (MR); cine study;
D O I
10.1148/radiology.177.3.2243988
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, the authors compared a new rapid spin-echo magnetic resonance (MR) imaging method, biphasic MR, with cine MR in the determination of left ventricular volume and mass in healthy volunteers. Biphasic spin-echo MR images covering the entire heart were obtained with use of the electrocardiogram R wave and the downslope of the T wave at both end diastole and end systole, respectively. Biphasic MR-determined values correlated well with small standard errors of the estimate (end-diastolic volume = 7.82 cm3, end-systolic volume = 3.35 cm3, end-diastolic mass = 10.20 g, end-systolic mass = 10.08 g, ejection fraction = 2.62%) and were more reproducible. Cine MR-defined end-systolic volume was significantly larger (P < .01) and ejection fraction was significantly smaller (P < .005) than biphasic MR-determined values probably because of the uncertainty in isolating end systole with cine MR. Left ventricular volumes, mass, and ejection fraction are more accurately and reproducibly quantified in a more time-efficient manner with use of biphasic MR than with cine MR because of its significantly shorter image acquisition and reconstruction times.
引用
收藏
页码:773 / 777
页数:5
相关论文
共 26 条
  • [1] BIRD BF, 1985, AM J CARDIOL, V55, P1440
  • [2] SELECTION OF OPTIMUM CINERADIOGRAPHIC FRAME RATE - RELATION TO ACCURACY OF CARDIAC MEASUREMENTS
    BOVE, AA
    ZISKIN, MC
    FREEMAN, E
    GIMENEZ, JL
    LYNCH, PR
    [J]. INVESTIGATIVE RADIOLOGY, 1970, 5 (05) : 329 - &
  • [3] NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE
    BUSER, PT
    AUFFERMANN, W
    HOLT, WW
    WAGNER, S
    KIRCHER, B
    WOLFE, C
    HIGGINS, CB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) : 1294 - 1300
  • [4] MAGNETIC-RESONANCE IMAGING STRATEGIES FOR HEART STUDIES
    CROOKS, LE
    BARKER, B
    CHANG, H
    FEINBERG, D
    HOENNINGER, JC
    WATTS, JC
    MITSUAKI, A
    KAUFMAN, L
    SHELDON, PE
    BOTVINICK, E
    HIGGINS, CB
    [J]. RADIOLOGY, 1984, 153 (02) : 459 - 465
  • [5] MAGNETIC-RESONANCE IMAGING OF THE HEART USING IMAGE PLANES ORIENTED TO CARDIAC AXES - EXPERIENCE WITH 100 CASES
    DINSMORE, RE
    WISMER, GL
    MILLER, SW
    THOMPSON, R
    JOHNSTON, DL
    LIU, P
    OKADA, RD
    SAINI, S
    BRADY, TJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (06) : 1177 - 1183
  • [6] COMPARISON OF MAGNETIC-RESONANCE IMAGING AND ECHOCARDIOGRAPHY IN DETERMINATION OF CARDIAC DIMENSIONS IN NORMAL SUBJECTS
    FRIEDMAN, BJ
    WATERS, J
    KWAN, OL
    DEMARIA, AN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (06) : 1369 - 1376
  • [7] REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    GORDON, EP
    SCHNITTGER, I
    FITZGERALD, PJ
    WILLIAMS, P
    POPP, RL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) : 506 - 513
  • [8] FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES
    HAASE, A
    FRAHM, J
    MATTHAEI, D
    HANICKE, W
    MERBOLDT, KD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) : 258 - 266
  • [9] HAMILTON GW, 1987, NUCLEAR CARDIOLOGY S, P75
  • [10] Higgins C B, 1988, Int J Card Imaging, V3, P21, DOI 10.1007/BF01801641