TREE-STRUCTURED VECTOR QUANTIZATION OF CT CHEST SCANS - IMAGE QUALITY AND DIAGNOSTIC-ACCURACY

被引:29
作者
COSMAN, PC
TSENG, C
GRAY, RM
OLSHEN, RA
MOSES, LE
DAVIDSON, HC
BERGIN, CJ
RISKIN, EA
机构
[1] STANFORD UNIV,SCH MED,DIV BIOSTAT,STANFORD,CA 94305
[2] STANFORD UNIV,SCH MED,DEPT DIAGNOST RADIOL & NUCL MED,STANFORD,CA 94305
[3] STANFORD UNIV,SCH MED,DIV DIAGNOST RADIOL,STANFORD,CA
[4] UNIV WASHINGTON,DEPT ELECT ENGN,SEATTLE,WA 98195
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
D O I
10.1109/42.251124
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The quality of lossy compressed images is often characterized by signal-to-noise ratios, informal tests of subjective quality, or receiver operating characteristic (ROC) curves that include subjective appraisals of the value of an image for a particular application. We believe that for medical applications, lossy compressed images should be judged by a more natural and fundamental aspect of relative image quality: their use in making accurate diagnoses. We apply a lossy compression algorithm to medical images, and quantify the quality of the images by the diagnostic performance of radiologists, as well as by traditional signal-to-noise ratios and subjective ratings. Our study is unlike previous studies of the effects of lossy compression in that we consider non-binary detection tasks, simulate actual diagnostic practice instead of using paired tests or confidence rankings, use statistical methods that are more appropriate for non-binary clinical data than are the popular ROC curves, and use low-complexity predictive tree-structured vector quantization for compression rather than DCT-based transform codes combined with entropy coding. Our diagnostic tasks are the identification of nodules (tumors) in the lungs and lymphadenopathy in the mediastinum from computerized tomography (CT) chest scans. Radiologists read both uncompressed and lossy compressed versions of images. For the image modality, compression algorithm, and diagnostic tasks we consider, the original 12 bit per pixel (bpp) CT image can be compressed to between 1 bpp and 2 bpp with no significant changes in diagnostic accuracy. The techniques presented in this paper for evaluating image quality do not depend on the specific compression algorithm and are useful new methods for evaluating the benefits of any lossy image processing technique.
引用
收藏
页码:727 / 739
页数:13
相关论文
共 37 条
  • [1] [Anonymous], 1992, SPRINGER INT
  • [2] ARMITAGE P, 1971, STATISTICAL METHODS
  • [3] BARRETT HH, 1991, 1991 P INT C INF PRO, P458
  • [4] IMAGE DATA-COMPRESSION IN MAGNIFICATION HAND RADIOGRAPHS
    BRAMBLE, JM
    COOK, LT
    MURPHEY, MD
    MARTIN, NL
    ANDERSON, WH
    HENSLEY, KS
    [J]. RADIOLOGY, 1989, 170 (01) : 133 - 136
  • [5] Breiman L, 2017, CLASSIFICATION REGRE, P368, DOI 10.1201/9781315139470
  • [6] FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT
    CHAKRABORTY, DP
    WINTER, LHL
    [J]. RADIOLOGY, 1990, 174 (03) : 873 - 881
  • [7] CHEN J, 1991, P SOC PHOTO-OPT INS, V1444, P256
  • [8] OPTIMAL PRUNING WITH APPLICATIONS TO TREE-STRUCTURED SOURCE-CODING AND MODELING
    CHOU, PA
    LOOKABAUGH, T
    GRAY, RM
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 1989, 35 (02) : 299 - 315
  • [9] COMBINING VECTOR QUANTIZATION AND HISTOGRAM EQUALIZATION
    COSMAN, PC
    RISKIN, EA
    GRAY, RM
    [J]. INFORMATION PROCESSING & MANAGEMENT, 1992, 28 (06) : 681 - 686
  • [10] COSMAN PC, 1993, THESIS STANFORD U