POSSIBILITIES OF THE GUARD RING FOR ELECTRICAL SIGNAL CONFINEMENT IN THE POLARIZATION MEASUREMENTS OF REINFORCEMENTS

被引:27
作者
FELIU, S [1 ]
GONZALEZ, JA [1 ]
ESCUDERO, ML [1 ]
FELIU, S [1 ]
ANDRADE, MC [1 ]
机构
[1] CSIC,INST CONSTRUCT & CEMENT,E-28022 MADRID,SPAIN
关键词
ELECTRICAL SIGNAL CONFINEMENT; GUARD RING; POLARIZATION MEASUREMENTS; REBAR CORROSION;
D O I
10.5006/1.3585049
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The technical possibilities of the "guard ring" for the local measurement of polarization resistance (R(p)) are analyzed for the purpose of determining the corrosion rate of rebar in large reinforced concrete structures. Based on tests carried out with reinforced concrete slabs as well as with an electrical analogue, it is concluded that the supposed confinement capacity of the electrical signal under the central counterelectrode is nearly guaranteed only in the event of low R(p) values. On the other hand, with high R(p) values, the electrical signal can extend way beyond the guard ring itself.
引用
收藏
页码:1015 / 1020
页数:6
相关论文
共 6 条
[1]   QUANTITATIVE MEASUREMENTS OF CORROSION RATE OF REINFORCING STEELS EMBEDDED IN CONCRETE USING POLARIZATION RESISTANCE MEASUREMENTS [J].
ANDRADE, C ;
GONZALEZ, JA .
WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1978, 29 (08) :515-519
[2]  
ESCALANTE E, 1980, NBS IR802012
[3]   ON-SITE DETERMINATION OF THE POLARIZATION RESISTANCE IN A REINFORCED-CONCRETE BEAM [J].
FELIU, S ;
GONZALEZ, JA ;
ANDRADE, C ;
FELIU, V .
CORROSION, 1988, 44 (10) :761-765
[4]   DETERMINING POLARIZATION RESISTANCE IN REINFORCED-CONCRETE SLABS [J].
FELIU, S ;
GONZALEZ, JA ;
ANDRADE, MC ;
FELIU, V .
CORROSION SCIENCE, 1989, 29 (01) :105-113
[5]   ELECTROCHEMICAL POLARIZATION .1. A THEORETICAL ANALYSIS OF THE SHAPE OF POLARIZATION CURVES [J].
STERN, M ;
GEARY, AL .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1957, 104 (01) :56-63
[6]  
WENGER F, 1987, MET CORROS-IND, V62, P307