QUANTITATIVE-ANALYSIS OF DYSTROPHIN GENE AMPLIFICATION PRODUCTS USING A PC-BASED IMAGE-ANALYSIS SYSTEM

被引:4
作者
MINAMIKAWATACHINO, R
ISHII, K
SAKURABA, H
SUZUKI, Y
KAMINUMA, T
机构
[1] TOKYO METROPOLITAN INST MED SCI,DEPT CLIN GENET,TOKYO 113,JAPAN
[2] NATL INST HYG SCI,DIV CHEMBIO INFORMAT,TOKYO 158,JAPAN
来源
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING | 1993年 / 33卷 / 3-4期
关键词
DUCHENNE BECKER MUSCULAR DYSTROPHY; GENE DOSAGE; POLYMERASE CHAIN REACTION; PERSONAL COMPUTER; IMAGE ANALYSIS; CCD CAMERA;
D O I
10.1016/0020-7101(93)90041-4
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A PC-based image analysis system for gel photographs of DNA gel patterns was developed. It was originally designed as a general-purpose, low-cost, yet high-performance system for wide applications in the biomedical area. In this study, we performed analysis of gel images obtained by polymerase chain reaction (PCR) amplification. The system employs a high-resolution CCD camera that can accurately measure grayness of the gel photographs for quantitative analysis of PCR products. The target DNA (exon 52 of the dystrophin gene), which had been found to be deleted in some patients with Duchenne/Becker muscular dystrophy (DMD/BMD), was amplified for the female family members together with the control DNA (exon 60) as a reference. The ratio of the target DNA to the control DNA was determined from PCR products to identify the carrier status of this disease by means of gene dosage. We conclude that 'the PC-based image analysis system' was useful for quantitative deletion analysis of DMD/BMD heterozygotes.
引用
收藏
页码:277 / 286
页数:10
相关论文
共 13 条
[1]  
ALDRIDGE J, 1984, AM J HUM GENET, V36, P546
[2]  
BEGGS AH, 1990, HUM GENET, V86, P45
[3]  
CANNON TM, 1991, BIOTECHNIQUES, V10, P764
[4]   DELETION SCREENING OF THE DUCHENNE MUSCULAR-DYSTROPHY LOCUS VIA MULTIPLEX DNA AMPLIFICATION [J].
CHAMBERLAIN, JS ;
GIBBS, RA ;
RANIER, JE ;
NGUYEN, PN ;
CASKEY, CT .
NUCLEIC ACIDS RESEARCH, 1988, 16 (23) :11141-11156
[5]  
HARPER PS, 1989, METABOLIC BASIS INHE, P2869
[6]   CARRIER DETECTION OF DUCHENNE-BECKER MUSCULAR-DYSTROPHY - COMPUTER-ASSISTED DIRECT QUANTITATION OF GENE AMPLIFICATION PRODUCTS [J].
ISHII, K ;
SAKURABA, H ;
MINAMIKAWATACHINO, R ;
SHIMMOTO, M ;
SUZUKI, Y .
BRAIN & DEVELOPMENT, 1992, 14 (02) :80-83
[7]  
KOENIG M, 1989, AM J HUM GENET, V45, P498
[8]  
QUESADA MA, 1991, BIOTECHNIQUES, V10, P616
[9]  
REDMAN T, 1991, BIOTECHNIQUES, V10, P790
[10]   PRIMER-DIRECTED ENZYMATIC AMPLIFICATION OF DNA WITH A THERMOSTABLE DNA-POLYMERASE [J].
SAIKI, RK ;
GELFAND, DH ;
STOFFEL, S ;
SCHARF, SJ ;
HIGUCHI, R ;
HORN, GT ;
MULLIS, KB ;
ERLICH, HA .
SCIENCE, 1988, 239 (4839) :487-491