Automated determination of tin by hydride generation using in situ trapping on stable coatings in graphite furnace atomic absorption spectrometry

被引:53
作者
Haug, HO
Liao, YP
机构
[1] Forschungszentrum Karlsruhe, Institut für Technische Chemie, D-76021 Karlsruhe
关键词
atomic absorption spectrometry; graphite furnace atomizer; in situ hydride trapping; long-term trapping reagents; tin hydride;
D O I
10.1016/0584-8547(95)01355-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Conditions have been studied for the determination of Sn by coupling of hydride generation and graphite furnace atomic absorption spectrometry. Sequestering and in situ concentration of Sn hydride in the graphite furnace requires just a single application of a long-term stable trapping reagent for automated analyses. In a systematic study it is shown that effective trapping of stannane is possible on graphite tubes or platforms coated with a carbide-forming element such as Zr, Nb, Ta, or W at trapping temperatures of 500 to 600 degrees C. Trapping temperatures should not be higher than 600 degrees C (the ''critical temperature'') because otherwise at temperatures higher than 700 degrees C errors in absorbance values could occur by an adsorptive ''carry-over effect''. Signal stability and reproducibility are tested over more than 400 complete trapping and atomization cycles, and a precision of 2% is observed. Narrow peaks are obtained for all coatings except for Nb- and Ta-coated platforms where double peaks occur. Ir- or Pd/Ir-coated surfaces allow trapping of stannane at lower temperatures but the signal stability (especially in the case of Pd/Ir coating) is lower than with the carbide-forming element coatings. The highest sensitivity is found for Zr- and W-coated tubes with a characteristic mass of about 17 and 20 pg, respectively, and the calibration curves are linear up to 2 ng Sn on Zr-treated tubes (peak height) and 4 ng on Zr-coated platforms (integrated absorbance) using the 286.3 nm line. The detection limit is 25 pg for a 1 mi sample volume, and the reagent blank is still significant with the purest available chemicals. The method is tested by determination of Sn in low alloy steel samples.
引用
收藏
页码:1311 / 1324
页数:14
相关论文
共 32 条
[1]  
BEACH L, 1992, AA107 VAR APPL NOT
[2]  
BEACH LM, 1987, SPECTROSCOPY, V2, P21
[3]   SENSITIVE ATOMIC-ABSORPTION SPECTROMETRIC METHOD FOR THE DETERMINATION OF TIN WITH ATOMIZATION FROM IMPREGNATED GRAPHITE SURFACES [J].
FRITZSCHE, H ;
WEGSCHEIDER, W ;
KNAPP, G ;
ORTNER, HM .
TALANTA, 1979, 26 (03) :219-226
[4]   SYSTEMATIC STUDIES ON THE DETERMINATION OF GERMANIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY INCLUDING LIQUID SAMPLE INTRODUCTION AND HYDRIDE TECHNIQUES [J].
HAUG, HO ;
JU, CH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (03) :215-223
[5]  
HOCQUELLET P, 1985, ATOM SPECTROSC, V6, P69
[6]   DETERMINATION OF TIN BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITH A TUNGSTEN-COATED TUBE [J].
IWAMOTO, E ;
SHIMAZU, H ;
YOKOTA, K ;
KUMAMARU, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :421-424
[7]  
LI SY, 1992, GUANGPUXUE YU GUANGP, V12, P117
[8]   THE DETERMINATION OF TIN IN STEEL SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROSCOPY [J].
MCINTOSH, S ;
LI, Z ;
CARNRICK, GR ;
SLAVIN, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :897-906
[9]   TANTALUM CARBIDE COATED PLATFORMS FOR ATOMIC-ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL ATOMIZATION - PERFORMANCE-CHARACTERISTICS FOR TIN, SELENIUM AND RHODIUM [J].
MICHAELIS, MRA ;
WEGSCHEIDER, W ;
ORTNER, HM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :503-509
[10]  
NAKAHARA T, 1983, PROG ANAL ATOM SPECT, V6, P163